Comparative study of a microdosimetric biological weighting function for RBE<sub>10</sub> modeling in particle therapy with a solid state SOI microdosimeter
<i>Objective:</i>the recently developed V79-RBE<sub>10</sub>biological weighting function (BWF) model is a simple and robust tool for a fast relative biological effectiveness (RBE) assessment for comparing different exposure conditions in particle therapy. In this study, the RBE<sub>10</sub>derived by this model (through the particle and heavy ion transport code system (PHITS) simulated<i>d(y)</i>spectra) is compared with values of RBE<sub>10</sub>using experimentally derived<i>d(y)</i>spectra from a silicon-on-insulator (SOI) microdosimeter.<i>Approach:</i>experimentally measured<i>d(y)</i>spectra are used to calculate an RBE<sub>10</sub>value utilizing the V79-RBE<sub>10</sub>BWF model as well as the modified microdosimetric kinetic model (MKM) to produce an RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for a wide range of ions. In addition, a beamline specific PHITS simulation was conducted which replicated the exact experimental conditions that were used with the SOI microdosimeter at the heavy ion medical accelerator in Chiba biological beamline with<sup>12</sup>C ions.<i>Main Results:</i>the RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>14</sup>N,<sup>16</sup>O,<sup>20</sup>Ne,<sup>28</sup>Si,<sup>56</sup>Fe, and<sup>124</sup>Xe ions is examined with good agreement found between the SOI microdosimeter derived RBE<sub>10</sub>values with the V79-RBE<sub>10</sub>BWF model and MKM, as well as the PHITS simulations for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>16</sup>O, and<sup>56</sup>Fe ions while some discrepancies were seen for<sup>14</sup>N,<sup>20</sup>Ne, and<sup>28</sup>Si ions. Deviations have been attributed to the difference in the derivation of the<i>d</i>(<i>y</i>) spectra based on the different methods utilized. Good agreement was found between<i>y</i><sub><i>D</i></sub>values and an over estimation was observed for RBE<sub>10</sub>values for the beamline specific simulation of the<sup>12</sup><i>C</i>ion beam.<i>Significance:</i>overall, this study shows that the SOI microdosimeter is a valuable tool that can be utilized for quick and accurate experimental derivation of the<i>d</i>(<i>y</i>) spectra, which can then be convoluted with the weighting function of the V79-RBE<sub>10</sub>BWF model to derive RBE<sub>10</sub>. The SOI microdosimeter is able to derive experimental values of<i>y</i><sub><i>D</i></sub>and RBE<sub>10</sub>for various ions in any irradiation condition utilizing other radiobiological models.
Authors
- David Bolst (ORCID: https://orcid.org/0000-0002-0257-1267)
- Taku Inaniwa (ORCID: https://orcid.org/0000-0002-2967-4004)
- Michael Jackson (ORCID: https://orcid.org/0000-0002-9201-4738)
- Alessio Parisi (ORCID: https://orcid.org/0000-0002-9323-8012)
- Vladimir Pan (ORCID: https://orcid.org/0000-0002-0482-3229)
- Anatoly Rosenfeld (ORCID: https://orcid.org/0000-0001-5116-6308)
- Linh T. Tran (ORCID: https://orcid.org/0000-0002-3321-2611)
- Jesse Williams
- Verity Ahren
Institutions
- The University of Sydney (AU)
- University of Wollongong (AU)
- Jacksonville College (US)
- UNSW Sydney (AU)
- Prince of Wales Hospital (AU)
- National Institutes for Quantum Science and Technology (JP)
- Belgian Nuclear Research Centre (BE)
- Mayo Clinic in Florida (US)
- Western Sydney University (AU)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2024-12-13
- DOI
- https://doi.org/10.1088/1361-6560/ad9f1c
- Citations
- 1
- Primary Topic
- Radiation Therapy and Dosimetry
- Type
- article
- Field-Weighted Citation Impact
- 0.42
Funders
- Cancer Institute NSW
- National Health and Medical Research Council