Comparative study of a microdosimetric biological weighting function for RBE<sub>10</sub> modeling in particle therapy with a solid state SOI microdosimeter

<i>Objective:</i>the recently developed V79-RBE<sub>10</sub>biological weighting function (BWF) model is a simple and robust tool for a fast relative biological effectiveness (RBE) assessment for comparing different exposure conditions in particle therapy. In this study, the RBE<sub>10</sub>derived by this model (through the particle and heavy ion transport code system (PHITS) simulated<i>d(y)</i>spectra) is compared with values of RBE<sub>10</sub>using experimentally derived<i>d(y)</i>spectra from a silicon-on-insulator (SOI) microdosimeter.<i>Approach:</i>experimentally measured<i>d(y)</i>spectra are used to calculate an RBE<sub>10</sub>value utilizing the V79-RBE<sub>10</sub>BWF model as well as the modified microdosimetric kinetic model (MKM) to produce an RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for a wide range of ions. In addition, a beamline specific PHITS simulation was conducted which replicated the exact experimental conditions that were used with the SOI microdosimeter at the heavy ion medical accelerator in Chiba biological beamline with<sup>12</sup>C ions.<i>Main Results:</i>the RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>14</sup>N,<sup>16</sup>O,<sup>20</sup>Ne,<sup>28</sup>Si,<sup>56</sup>Fe, and<sup>124</sup>Xe ions is examined with good agreement found between the SOI microdosimeter derived RBE<sub>10</sub>values with the V79-RBE<sub>10</sub>BWF model and MKM, as well as the PHITS simulations for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>16</sup>O, and<sup>56</sup>Fe ions while some discrepancies were seen for<sup>14</sup>N,<sup>20</sup>Ne, and<sup>28</sup>Si ions. Deviations have been attributed to the difference in the derivation of the<i>d</i>(<i>y</i>) spectra based on the different methods utilized. Good agreement was found between<i>y</i><sub><i>D</i></sub>values and an over estimation was observed for RBE<sub>10</sub>values for the beamline specific simulation of the<sup>12</sup><i>C</i>ion beam.<i>Significance:</i>overall, this study shows that the SOI microdosimeter is a valuable tool that can be utilized for quick and accurate experimental derivation of the<i>d</i>(<i>y</i>) spectra, which can then be convoluted with the weighting function of the V79-RBE<sub>10</sub>BWF model to derive RBE<sub>10</sub>. The SOI microdosimeter is able to derive experimental values of<i>y</i><sub><i>D</i></sub>and RBE<sub>10</sub>for various ions in any irradiation condition utilizing other radiobiological models.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-13
DOI
https://doi.org/10.1088/1361-6560/ad9f1c
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative study of a microdosimetric biological weighting function for RBE10 modeling in particle therapy with a solid state SOI microdosimeter

David Bolst, Taku Inaniwa, Michael Jackson, Alessio Parisi et al.
1 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
0.42
article

Comparative study of a microdosimetric biological weighting function for RBE10 modeling in particle therapy with a solid state SOI microdosimeter

David Bolst, Taku Inaniwa, Michael Jackson, Alessio Parisi, Vladimir Pan, Anatoly Rosenfeld, Linh T. Tran, Jesse Williams, Verity Ahren
article en
1 citations

Abstract

<i>Objective:</i>the recently developed V79-RBE<sub>10</sub>biological weighting function (BWF) model is a simple and robust tool for a fast relative biological effectiveness (RBE) assessment for comparing different exposure conditions in particle therapy. In this study, the RBE<sub>10</sub>derived by this model (through the particle and heavy ion transport code system (PHITS) simulated<i>d(y)</i>spectra) is compared with values of RBE<sub>10</sub>using experimentally derived<i>d(y)</i>spectra from a silicon-on-insulator (SOI) microdosimeter.<i>Approach:</i>experimentally measured<i>d(y)</i>spectra are used to calculate an RBE<sub>10</sub>value utilizing the V79-RBE<sub>10</sub>BWF model as well as the modified microdosimetric kinetic model (MKM) to produce an RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for a wide range of ions. In addition, a beamline specific PHITS simulation was conducted which replicated the exact experimental conditions that were used with the SOI microdosimeter at the heavy ion medical accelerator in Chiba biological beamline with<sup>12</sup>C ions.<i>Main Results:</i>the RBE<sub>10</sub>-vs-<i>y</i><sub><i>D</i></sub>trend for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>14</sup>N,<sup>16</sup>O,<sup>20</sup>Ne,<sup>28</sup>Si,<sup>56</sup>Fe, and<sup>124</sup>Xe ions is examined with good agreement found between the SOI microdosimeter derived RBE<sub>10</sub>values with the V79-RBE<sub>10</sub>BWF model and MKM, as well as the PHITS simulations for<sup>1</sup>H,<sup>4</sup>He,<sup>7</sup>Li,<sup>12</sup>C,<sup>16</sup>O, and<sup>56</sup>Fe ions while some discrepancies were seen for<sup>14</sup>N,<sup>20</sup>Ne, and<sup>28</sup>Si ions. Deviations have been attributed to the difference in the derivation of the<i>d</i>(<i>y</i>) spectra based on the different methods utilized. Good agreement was found between<i>y</i><sub><i>D</i></sub>values and an over estimation was observed for RBE<sub>10</sub>values for the beamline specific simulation of the<sup>12</sup><i>C</i>ion beam.<i>Significance:</i>overall, this study shows that the SOI microdosimeter is a valuable tool that can be utilized for quick and accurate experimental derivation of the<i>d</i>(<i>y</i>) spectra, which can then be convoluted with the weighting function of the V79-RBE<sub>10</sub>BWF model to derive RBE<sub>10</sub>. The SOI microdosimeter is able to derive experimental values of<i>y</i><sub><i>D</i></sub>and RBE<sub>10</sub>for various ions in any irradiation condition utilizing other radiobiological models.

Physics in Medicine and BiologyVol. 70(1)
The University of Sydney (AU), University of Wollongong (AU), Jacksonville College (US), UNSW Sydney (AU), Prince of Wales Hospital (AU), National Institutes for Quantum Science and Technology (JP), Belgian Nuclear Research Centre (BE), Mayo Clinic in Florida (US), Western Sydney University (AU)
Cancer Institute NSW, National Health and Medical Research Council
Openalex Percentile: Top 30%
Radiation Therapy and Dosimetry
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.