Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200

This study aimed to evaluate the analytical performance of the serum phosphorus assay using the Abbott Architect ci8200® automated system in the biochemistry laboratory of CHU Mohammed VI, Oujda. Method verification was conducted following NF ISO 15189 standards and COFRAC guidelines, assessing key performance parameters such as repeatability, reproducibility, and measurement uncertainty. The colorimetric method for phosphorus determination demonstrated excellent precision, with coefficients of variation (CV) for repeatability ranging from 0.93% to 1.06% across low, medium, and high concentrations. Reproducibility assessments yielded CVs between 2.07% and 2.53%, indicating robust intra-laboratory performance. A comparative analysis between systems using the Bland-Altman method showed strong agreement, with a correlation coefficient of 0.997. Measurement uncertainties at all levels were within acceptable limits. These findings confirm the reliability and accuracy of the assay, highlighting its suitability for clinical diagnostics and its alignment with international accreditation standards.

Authors

Publication Details

Journal
World Journal of Biology Pharmacy and Health Sciences
Published
2024-12-13
DOI
https://doi.org/10.30574/wjbphs.2024.20.3.0983
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200

Sabrina Belmahi, Oumaima Nassiri, Amjad Idrissi, El-houcine Sebbar et al.
World Journal of Biology Pharmacy and Health Sciences
Clinical Laboratory Practices and Quality Control
article

Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200

Sabrina Belmahi, Oumaima Nassiri, Amjad Idrissi, El-houcine Sebbar, Abdessamad Amrani, Mohammed Choukri
article en

Abstract

This study aimed to evaluate the analytical performance of the serum phosphorus assay using the Abbott Architect ci8200® automated system in the biochemistry laboratory of CHU Mohammed VI, Oujda. Method verification was conducted following NF ISO 15189 standards and COFRAC guidelines, assessing key performance parameters such as repeatability, reproducibility, and measurement uncertainty. The colorimetric method for phosphorus determination demonstrated excellent precision, with coefficients of variation (CV) for repeatability ranging from 0.93% to 1.06% across low, medium, and high concentrations. Reproducibility assessments yielded CVs between 2.07% and 2.53%, indicating robust intra-laboratory performance. A comparative analysis between systems using the Bland-Altman method showed strong agreement, with a correlation coefficient of 0.997. Measurement uncertainties at all levels were within acceptable limits. These findings confirm the reliability and accuracy of the assay, highlighting its suitability for clinical diagnostics and its alignment with international accreditation standards.

World Journal of Biology Pharmacy and Health SciencesVol. 20(3)
Openalex Percentile: Top 68%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification of the analytical performance of the serum phosphorus assay on Abbott Architect ci8200 — Sabrina Belmahi, Oumaima Nassiri, et al. · World Journal of Biology Pharmacy and Health Sciences (2024) | TGRS Research Map | TGRS