Switch Fault Diagnosis for Switched Reluctance Motors Based on Current Double-Measurement

Fault diagnosis of power switches is essential for enhancing the reliability of switched reluctance motor (SRM) systems. This article proposes a novel double-measurement-based switch fault diagnosis method for SRM drives based on double-measurement. This method uses double-measurement of current information, which does not require additional sensors or detection circuits. First, an analysis and measurement of phase current are conducted using the proposed double-measurement method. Then, the implementation principles of the fault diagnosis method are illustrated. In addition, the application analysis is provided in detail for SRMs with different control strategies and chopping modes. Furthermore, the phase current detection can be effectively performed under switch fault conditions. Finally, experiments using an 8/6 four-phase SRM are conducted to validate the effectiveness of the proposed fault diagnosis method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2024-12-13
DOI
https://doi.org/10.1109/tpel.2024.3517575
Citations
3
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Switch Fault Diagnosis for Switched Reluctance Motors Based on Current Double-Measurement

Ge Qi, Shuai Xu, Guoqiang Han, Chen Liu et al.
3 citations
IEEE Transactions on Power Electronics
Non-Destructive Testing Techniques
0.64
article

Switch Fault Diagnosis for Switched Reluctance Motors Based on Current Double-Measurement

Ge Qi, Shuai Xu, Guoqiang Han, Chen Liu, Fuhu Song
article en
3 citations

Abstract

Fault diagnosis of power switches is essential for enhancing the reliability of switched reluctance motor (SRM) systems. This article proposes a novel double-measurement-based switch fault diagnosis method for SRM drives based on double-measurement. This method uses double-measurement of current information, which does not require additional sensors or detection circuits. First, an analysis and measurement of phase current are conducted using the proposed double-measurement method. Then, the implementation principles of the fault diagnosis method are illustrated. In addition, the application analysis is provided in detail for SRMs with different control strategies and chopping modes. Furthermore, the phase current detection can be effectively performed under switch fault conditions. Finally, experiments using an 8/6 four-phase SRM are conducted to validate the effectiveness of the proposed fault diagnosis method.

IEEE Transactions on Power ElectronicsVol. 40(4)
China University of Mining and Technology (CN), Zhengzhou University (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 34%
Non-Destructive Testing Techniques
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.