Exposure rate response analysis of criticality accident detector at Savannah River Site
This analysis investigated the exposure response behavior of gamma-ray ionization chambers used in the criticality accident systems at the Savannah River Site (SRS). The project consisted of performing exposure response measurements with a calibrated <sup>137</sup>Cs source for benchmarking of the MCNP Monte Carlo code. MCNP was then used to extrapolate the ion chamber's response to gamma-rays with energies outside the current domain of measured data for criticality fission sources.
Authors
- J.F. Zino
Institutions
- Westinghouse Electric (United States) (US)
Publication Details
- Journal
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
- Published
- 2024-12-11
- Primary Topic
- Risk and Safety Analysis
- Type
- article