Reconciling predicted and measured viscosity parameters in high concentration therapeutic antibody solutions

Monoclonal antibody (mAb) solution viscosity in ultra-high concentration formulations is a key developability consideration in mAb development risk mitigation strategies that has implications for downstream processing and patient safety. Predicting viscosity at therapeutically relevant concentrations remains critical, despite the need for large mAb quantities for viscosity measurement being prohibitive. Using a panel of IgG1s, we examined the suitability of viscosity prediction and fitting models at different mAb test concentration regimes. Our findings caution against extrapolation from low concentration measurements, as they lack predictive ability for ultra-high concentration regimes. For the first time, we demonstrate the importance of analyte concentration range selection, and the need for bespoke viscosity model development.

Authors

Institutions

Publication Details

Journal
mAbs
Published
2024-12-11
DOI
https://doi.org/10.1080/19420862.2024.2438172
Citations
6
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
1.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconciling predicted and measured viscosity parameters in high concentration therapeutic antibody solutions

Georgina B. Armstrong, Aisling Roche, Zahra Rattray, William Lewis
6 citations
mAbs
Protein purification and stability
1.40
article

Reconciling predicted and measured viscosity parameters in high concentration therapeutic antibody solutions

Georgina B. Armstrong, Aisling Roche, Zahra Rattray, William Lewis
article en
6 citations

Abstract

Monoclonal antibody (mAb) solution viscosity in ultra-high concentration formulations is a key developability consideration in mAb development risk mitigation strategies that has implications for downstream processing and patient safety. Predicting viscosity at therapeutically relevant concentrations remains critical, despite the need for large mAb quantities for viscosity measurement being prohibitive. Using a panel of IgG1s, we examined the suitability of viscosity prediction and fitting models at different mAb test concentration regimes. Our findings caution against extrapolation from low concentration measurements, as they lack predictive ability for ultra-high concentration regimes. For the first time, we demonstrate the importance of analyte concentration range selection, and the need for bespoke viscosity model development.

mAbsVol. 16(1)
University of Strathclyde (GB), GlaxoSmithKline (United Kingdom) (GB), GlaxoSmithKline (Netherlands) (NL)
GlaxoSmithKline, Directorate for Biological Sciences, Engineering and Physical Sciences Research Council, Biotechnology and Biological Sciences Research Council
Zero hunger
Openalex Percentile: Top 18%
Protein purification and stability
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reconciling predicted and measured viscosity parameters in high concentration therapeutic antibody solutions — Georgina B. Armstrong, Aisling Roche, et al. · mAbs (2024) | TGRS Research Map | TGRS