Comparison of high-flow nasal oxygenation and standard low-flow nasal oxygenation during rigid bronchoscopy: a randomized controlled trial
While HFNO did not enhance the lowest SpO2 levels in comparison with standard low-flow oxygenation, it did reduce hypoxemia-related surgical interruptions with an attenuated decline in PaO2. Therefore, HFNO has considerable clinical efficacy for rigid bronchoscopy.
Authors
- Hye Jin Kim (ORCID: https://orcid.org/0000-0003-3452-477X)
- Namo Kim (ORCID: https://orcid.org/0000-0002-0829-490X)
- Young Jun Oh (ORCID: https://orcid.org/0000-0002-6258-5695)
- Seungyeon Lee (ORCID: https://orcid.org/0000-0001-6082-3082)
- Chang Young Lee (ORCID: https://orcid.org/0000-0002-2404-9357)
- Kyuho Lee (ORCID: https://orcid.org/0000-0003-0080-5426)
Institutions
- Yonsei University (KR)
Publication Details
- Journal
- Korean journal of anesthesiology
- Published
- 2024-12-12
- DOI
- https://doi.org/10.4097/kja.24517
- Citations
- 8
- Primary Topic
- Airway Management and Intubation Techniques
- Type
- article
- Field-Weighted Citation Impact
- 5.13