Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach

Aim: Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach. Materials and Methods: Our study included patients who underwent proximal humeral anatomic locking plate with deltopectoral approach due to proximal humeral fracture (PHF) between 2022-2023. Patient who attained skeletal maturity, with closed humeral fractures, isolated unilateral humerus fracture were included in our retrospective study. The functional outcome were compared with the contralateral normal side using the Constant-Marley score and radiological results with the full anteroposterior radiography and collodiaohyseal angles. Results: The Constant Murley scoring categorical data structure of the patients, the operated side was 6.1% (N=2) poor, 6.1% (N=2) moderate, 39.4% (N=12) good, 48.5% (N=16) excellent. Statistical difference was found between the operated side and the healthy side (p>0.05). While the mean Constant Murley score of the operated side was 85.82 ± 7.07, the mean Constant Murley score of the healthy side was 90.67±5.76. While the average of the collodiaphyseal angles of the operated side was 130.03±4.64; the mean of the angles of the intact side was 135.64±5.04. Conclusion: The Constant Murley scoring categorical data structure of the patients, the operated side was 6.1% (N=2) poor, 6.1% (N=2) moderate, 39.4% (N=12) good, 48.5% (N=16) excellent. Statistical It has been observed that both clinical and functional results of the patients were successful after plate osteosynthesis using the deltopectoral approach and proximal humerus anatomical locking plate in proximal humerus fractures.

Authors

Publication Details

Journal
International Journal of Orthopaedics Sciences
Published
2024-10-01
DOI
https://doi.org/10.22271/ortho.2024.v10.i4c.3637
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach

Shashiraj K Shetty, Sachin Shetty, D. Shetty, Akshitha
International Journal of Orthopaedics Sciences
Shoulder Injury and Treatment
article

Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach

Shashiraj K Shetty, Sachin Shetty, D. Shetty, Akshitha
article en

Abstract

Aim: Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach. Materials and Methods: Our study included patients who underwent proximal humeral anatomic locking plate with deltopectoral approach due to proximal humeral fracture (PHF) between 2022-2023. Patient who attained skeletal maturity, with closed humeral fractures, isolated unilateral humerus fracture were included in our retrospective study. The functional outcome were compared with the contralateral normal side using the Constant-Marley score and radiological results with the full anteroposterior radiography and collodiaohyseal angles. Results: The Constant Murley scoring categorical data structure of the patients, the operated side was 6.1% (N=2) poor, 6.1% (N=2) moderate, 39.4% (N=12) good, 48.5% (N=16) excellent. Statistical difference was found between the operated side and the healthy side (p>0.05). While the mean Constant Murley score of the operated side was 85.82 ± 7.07, the mean Constant Murley score of the healthy side was 90.67±5.76. While the average of the collodiaphyseal angles of the operated side was 130.03±4.64; the mean of the angles of the intact side was 135.64±5.04. Conclusion: The Constant Murley scoring categorical data structure of the patients, the operated side was 6.1% (N=2) poor, 6.1% (N=2) moderate, 39.4% (N=12) good, 48.5% (N=16) excellent. Statistical It has been observed that both clinical and functional results of the patients were successful after plate osteosynthesis using the deltopectoral approach and proximal humerus anatomical locking plate in proximal humerus fractures.

International Journal of Orthopaedics SciencesVol. 10(4)
Openalex Percentile: Top 57%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the functional and radiological results in the patients who came with proximal humerus fracture for which they underwent osteosynthesis plating with deltopectoral approach — Shashiraj K Shetty, Sachin Shetty, et al. · International Journal of Orthopaedics Sciences (2024) | TGRS Research Map | TGRS