Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration

A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-12-11
DOI
https://doi.org/10.3390/bios14120607
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration

Sergey L. Znoyko, A.M. Skirda, Petr I. Nikitin, А. В. Орлов et al.
4 citations
Biosensors
Advanced biosensing and bioanalysis techniques
0.94
article

Enhanced Analytical Performance in CYFRA 21-1 Detection Using Lateral Flow Assay with Magnetic Bioconjugates: Integration and Comparison of Magnetic and Optical Registration

Sergey L. Znoyko, A.M. Skirda, Petr I. Nikitin, А. В. Орлов, Juri A. Malkerov, Alexandra S. Rakitina
article en
4 citations

Abstract

A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique. For the first time in LFA applications, the MPQ-based and colorimetry-based detection methods were compared side by side, and superior analytical performance was demonstrated. The limit of detection (LOD) of 0.9 pg/mL was achieved using MPQ, and 2.9 pg/mL with optical detection. This study has demonstrated that MPQ provides elimination of signal saturation, higher sensitivity (slope of the calibration curve), and a 19-fold wider dynamic range of detected signals. Both optical and magnetic detection results are comparable to the best laboratory-based tests with the added benefits of a 20-min assay duration and the LFA format convenience. The assay effectiveness was validated in human serum and artificial saliva, and high recovery rates were observed. The proposed approach offers rapid and reliable detection of molecular biomarkers and holds significant potential for point-of-care diagnostics, particularly in resource-limited settings.

BiosensorsVol. 14(12)
Prokhorov General Physics Institute (RU), National Research Nuclear University MEPhI (RU)
Ministry of Science and Higher Education of the Russian Federation
Openalex Percentile: Top 24%
Advanced biosensing and bioanalysis techniques
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.