MFF-Net: A Lightweight Multi-Frequency Network for Measuring Heart Rhythm from Facial Videos

Remote photo-plethysmography (rPPG) is a useful camera-based health motioning method that can measure the heart rhythm from facial videos. Many well-established deep learning models can provide highly accurate and robust results in measuring heart rate (HR) and heart rate variability (HRV). However, these methods are unable to effectively eliminate illumination variation and motion artifact disturbances, and their substantial computational resource requirements significantly limit their applicability in real-world scenarios. Hence, we propose a lightweight multi-frequency network named MFF-Net to measure heart rhythm via facial videos in a short time. Firstly, we propose a multi-frequency mode signal fusion (MFF) mechanism, which can separate the characteristics of different modes of the original rPPG signals and send them to a processor with independent parameters, helping the network recover blood volume pulse (BVP) signals accurately under a complex noise environment. In addition, in order to help the network extract the characteristics of different modal signals effectively, we designed a temporal multiscale convolution module (TMSC-module) and spectrum self-attention module (SSA-module). The TMSC-module can expand the receptive field of the signal-refining network, obtain more abundant multiscale information, and transmit it to the signal reconstruction network. The SSA-module can help a signal reconstruction network locate the obvious inferior parts in the reconstruction process so as to make better decisions when merging multi-dimensional signals. Finally, in order to solve the over-fitting phenomenon that easily occurs in the network, we propose an over-fitting sampling training scheme to further improve the fitting ability of the network. Comprehensive experiments were conducted on three benchmark datasets, and we estimated HR and HRV based on the BVP signals derived by MFF-Net. Compared with state-of-the-art methods, our approach achieves better performance both on HR and HRV estimation with lower computational burden. We can conclude that the proposed MFF-Net has the opportunity to be applied in many real-world scenarios.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-12
DOI
https://doi.org/10.3390/s24247937
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MFF-Net: A Lightweight Multi-Frequency Network for Measuring Heart Rhythm from Facial Videos

Xiujuan Zheng, Wei Yan, Yun Zhang, Yuheng Chen et al.
2 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.37
article

MFF-Net: A Lightweight Multi-Frequency Network for Measuring Heart Rhythm from Facial Videos

Xiujuan Zheng, Wei Yan, Yun Zhang, Yuheng Chen, Jialiang Zhuang
article en
2 citations

Abstract

Remote photo-plethysmography (rPPG) is a useful camera-based health motioning method that can measure the heart rhythm from facial videos. Many well-established deep learning models can provide highly accurate and robust results in measuring heart rate (HR) and heart rate variability (HRV). However, these methods are unable to effectively eliminate illumination variation and motion artifact disturbances, and their substantial computational resource requirements significantly limit their applicability in real-world scenarios. Hence, we propose a lightweight multi-frequency network named MFF-Net to measure heart rhythm via facial videos in a short time. Firstly, we propose a multi-frequency mode signal fusion (MFF) mechanism, which can separate the characteristics of different modes of the original rPPG signals and send them to a processor with independent parameters, helping the network recover blood volume pulse (BVP) signals accurately under a complex noise environment. In addition, in order to help the network extract the characteristics of different modal signals effectively, we designed a temporal multiscale convolution module (TMSC-module) and spectrum self-attention module (SSA-module). The TMSC-module can expand the receptive field of the signal-refining network, obtain more abundant multiscale information, and transmit it to the signal reconstruction network. The SSA-module can help a signal reconstruction network locate the obvious inferior parts in the reconstruction process so as to make better decisions when merging multi-dimensional signals. Finally, in order to solve the over-fitting phenomenon that easily occurs in the network, we propose an over-fitting sampling training scheme to further improve the fitting ability of the network. Comprehensive experiments were conducted on three benchmark datasets, and we estimated HR and HRV based on the BVP signals derived by MFF-Net. Compared with state-of-the-art methods, our approach achieves better performance both on HR and HRV estimation with lower computational burden. We can conclude that the proposed MFF-Net has the opportunity to be applied in many real-world scenarios.

SensorsVol. 24(24)
Sichuan University (CN), Science and Technology Department of Sichuan Province (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 42%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.