Non-Invasive Glucose Measurement Technique Based on Time-of-Flight

A novel, low-cost sensor for the measurement of physiological levels of glucose in samples has been developed using Time-of-Flight (ToF) technology. The sensor, built with off-the-shelf components, leverages the scattering of light by glucose molecules to determine concentration changes by measuring the phase shift of light signals propagating through the sample. Experimental validation demonstrates the feasibility of this approach, correlating glucose concentration with optical scattering effects at a wavelength of 850 nm. This technique offers the potential for a cost-effective, non-invasive alternative to traditional methods of glucose monitoring, with applications in continuous glucose monitoring systems to improve diabetes management by reducing patient discomfort and enhancing monitoring accuracy. Further optimization of the sensor parameters and expanded testing are still needed.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-12
DOI
https://doi.org/10.3390/app142411602
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Glucose Measurement Technique Based on Time-of-Flight

Evangelos Hristoforou, Konstantinos Asimakopoulos
1 citations
Applied Sciences
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
article

Non-Invasive Glucose Measurement Technique Based on Time-of-Flight

Evangelos Hristoforou, Konstantinos Asimakopoulos
article en
1 citations

Abstract

A novel, low-cost sensor for the measurement of physiological levels of glucose in samples has been developed using Time-of-Flight (ToF) technology. The sensor, built with off-the-shelf components, leverages the scattering of light by glucose molecules to determine concentration changes by measuring the phase shift of light signals propagating through the sample. Experimental validation demonstrates the feasibility of this approach, correlating glucose concentration with optical scattering effects at a wavelength of 850 nm. This technique offers the potential for a cost-effective, non-invasive alternative to traditional methods of glucose monitoring, with applications in continuous glucose monitoring systems to improve diabetes management by reducing patient discomfort and enhancing monitoring accuracy. Further optimization of the sensor parameters and expanded testing are still needed.

Applied SciencesVol. 14(24)
National Technical University of Athens (GR)
State Scholarships Foundation, National Technical University of Athens
Good health and well-being
Openalex Percentile: Top 18%
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.