Beveled microneedles with channel for transdermal injection and sampling, fabricated with minimal steps and standard MEMS technology

Microneedles hold the potential for enabling shallow skin penetration applications where biomarkers are extracted from the interstitial fluid (ISF) and drugs are injected in a painless and effective manner. To this purpose, needles must have an inner channel. Channeled needles were demonstrated using custom silicon microtechnology, having several needle tip geometries. Nevertheless, all the proposed fabrication sequences are not compatible with mass production based on mature, standard microfabrication techniques. Furthermore, ISF extraction was also demonstrated with channeled needles but under poorly controlled conditions and over long periods of time, the latter being impractical for medical use. A range of factors may impede or slow ISF extraction that require controlled experiments. In this work we address the above tasks in terms of microfabrication sequence design, tip geometry design and experimental validation under controlled conditions. We report the development and fabrication of a silicon channeled microneedle array using conventional, industrial micromechanic processes. With only 2 lithography steps, a hypodermic needle tip profile is achieved. Using the fabricated microneedles, fluid extraction is experimented on chicken skin mockups. Extraction tests are carried out by inducing a controlled pressure gradient between the two ends of the microneedle channels, generated by loading the chip or by applying vacuum to the chip's backside. The extraction of more than 1 μL of fluid in 20 minutes is demonstrated with a maximum applied pressure gradient of 500 mbar. A correlation between the extraction rate efficiency and needles' density is observed, both for short and long extraction times. These results provide the first demonstration of <i>in vitro</i> interstitial fluid collection under controlled experimental conditions using silicon hollow microneedles fabricated with standard micro electro mechanical systems (MEMS) fabrication technology and minimal steps. Based on the obtained data, a comparison is drawn between pressure load and vacuum as drivers for ISF extraction, according to modelling and controlled experiments.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2024-12-12
DOI
https://doi.org/10.1039/d4lc00880d
Citations
1
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beveled microneedles with channel for transdermal injection and sampling, fabricated with minimal steps and standard MEMS technology

Nicolò G. Di Novo, Nicola M. Pugno, Matteo Valt, Cristian Collini et al.
1 citations
Lab on a Chip
Advancements in Transdermal Drug Delivery
0.21
article

Beveled microneedles with channel for transdermal injection and sampling, fabricated with minimal steps and standard MEMS technology

Nicolò G. Di Novo, Nicola M. Pugno, Matteo Valt, Cristian Collini, Alvise Bagolini, Severino Pedrotti, Leandro Lorenzelli
article en
1 citations

Abstract

Microneedles hold the potential for enabling shallow skin penetration applications where biomarkers are extracted from the interstitial fluid (ISF) and drugs are injected in a painless and effective manner. To this purpose, needles must have an inner channel. Channeled needles were demonstrated using custom silicon microtechnology, having several needle tip geometries. Nevertheless, all the proposed fabrication sequences are not compatible with mass production based on mature, standard microfabrication techniques. Furthermore, ISF extraction was also demonstrated with channeled needles but under poorly controlled conditions and over long periods of time, the latter being impractical for medical use. A range of factors may impede or slow ISF extraction that require controlled experiments. In this work we address the above tasks in terms of microfabrication sequence design, tip geometry design and experimental validation under controlled conditions. We report the development and fabrication of a silicon channeled microneedle array using conventional, industrial micromechanic processes. With only 2 lithography steps, a hypodermic needle tip profile is achieved. Using the fabricated microneedles, fluid extraction is experimented on chicken skin mockups. Extraction tests are carried out by inducing a controlled pressure gradient between the two ends of the microneedle channels, generated by loading the chip or by applying vacuum to the chip's backside. The extraction of more than 1 μL of fluid in 20 minutes is demonstrated with a maximum applied pressure gradient of 500 mbar. A correlation between the extraction rate efficiency and needles' density is observed, both for short and long extraction times. These results provide the first demonstration of <i>in vitro</i> interstitial fluid collection under controlled experimental conditions using silicon hollow microneedles fabricated with standard micro electro mechanical systems (MEMS) fabrication technology and minimal steps. Based on the obtained data, a comparison is drawn between pressure load and vacuum as drivers for ISF extraction, according to modelling and controlled experiments.

Lab on a ChipVol. 25(2)
Queen Mary University of London (GB), University of Trento (IT), Fondazione Bruno Kessler (IT)
Openalex Percentile: Top 48%
Advancements in Transdermal Drug Delivery
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.