NLP-Driven Analysis of Pneumothorax Incidence Following Central Venous Catheter Procedures: A Data-Driven Re-Evaluation of Routine Imaging in Value-Based Medicine

<b>Background</b>: This study presents a systematic approach using a natural language processing (NLP) algorithm to assess the necessity of routine imaging after central venous catheter (CVC) placement and removal. With pneumothorax being a key complication of CVC procedures, this research aims to provide evidence-based recommendations for optimizing imaging protocols and minimizing unnecessary imaging risks. <b>Methods:</b> We analyzed electronic health records from four university hospitals in Salzburg, Austria, focusing on X-rays performed between 2012 and 2021 following CVC procedures. A custom-built NLP algorithm identified cases of pneumothorax from radiologists' reports and clinician requests, while excluding cases with contraindications such as chest injuries, prior pneumothorax, or missing data. Chi-square tests were used to compare pneumothorax rates between CVC insertion and removal, and multivariate logistic regression identified risk factors, with a focus on age and gender. <b>Results</b>: This study analyzed 17,175 cases of patients aged 18 and older, with 95.4% involving CVC insertion and 4.6% involving CVC removal. Pneumothorax was observed in 106 cases post-insertion (1.3%) and in 3 cases post-removal (0.02%), with no statistically significant difference between procedures (<i>p</i> = 0.5025). The NLP algorithm achieved an accuracy of 93%, with a sensitivity of 97.9%, a specificity of 87.9%, and an area under the ROC curve (AUC) of 0.9283. <b>Conclusions</b>: The findings indicate no significant difference in pneumothorax incidence between CVC insertion and removal, supporting existing recommendations against routine imaging post-removal for asymptomatic patients and suggesting that routine imaging after CVC insertion may also be unnecessary in similar cases. This study demonstrates how advanced NLP techniques can support value-based medicine by enhancing clinical decision making and optimizing resources.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-12-12
DOI
https://doi.org/10.3390/diagnostics14242792
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NLP-Driven Analysis of Pneumothorax Incidence Following Central Venous Catheter Procedures: A Data-Driven Re-Evaluation of Routine Imaging in Value-Based Medicine

Christian Deininger, Teresa Wiesner, Vanessa Moore, Florian Wichlas et al.
Diagnostics
Central Venous Catheters and Hemodialysis
article

NLP-Driven Analysis of Pneumothorax Incidence Following Central Venous Catheter Procedures: A Data-Driven Re-Evaluation of Routine Imaging in Value-Based Medicine

Christian Deininger, Teresa Wiesner, Vanessa Moore, Florian Wichlas, Martin Breitwieser
article en

Abstract

<b>Background</b>: This study presents a systematic approach using a natural language processing (NLP) algorithm to assess the necessity of routine imaging after central venous catheter (CVC) placement and removal. With pneumothorax being a key complication of CVC procedures, this research aims to provide evidence-based recommendations for optimizing imaging protocols and minimizing unnecessary imaging risks. <b>Methods:</b> We analyzed electronic health records from four university hospitals in Salzburg, Austria, focusing on X-rays performed between 2012 and 2021 following CVC procedures. A custom-built NLP algorithm identified cases of pneumothorax from radiologists' reports and clinician requests, while excluding cases with contraindications such as chest injuries, prior pneumothorax, or missing data. Chi-square tests were used to compare pneumothorax rates between CVC insertion and removal, and multivariate logistic regression identified risk factors, with a focus on age and gender. <b>Results</b>: This study analyzed 17,175 cases of patients aged 18 and older, with 95.4% involving CVC insertion and 4.6% involving CVC removal. Pneumothorax was observed in 106 cases post-insertion (1.3%) and in 3 cases post-removal (0.02%), with no statistically significant difference between procedures (<i>p</i> = 0.5025). The NLP algorithm achieved an accuracy of 93%, with a sensitivity of 97.9%, a specificity of 87.9%, and an area under the ROC curve (AUC) of 0.9283. <b>Conclusions</b>: The findings indicate no significant difference in pneumothorax incidence between CVC insertion and removal, supporting existing recommendations against routine imaging post-removal for asymptomatic patients and suggesting that routine imaging after CVC insertion may also be unnecessary in similar cases. This study demonstrates how advanced NLP techniques can support value-based medicine by enhancing clinical decision making and optimizing resources.

DiagnosticsVol. 14(24)
Paracelsus Medical University (AT)
Openalex Percentile: Top 60%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.