Real-time automatic temperature monitoring in fiber laser ablation of biological tissue surgery

Real-time temperature monitoring during fiber laser ablation surgery on biological tissues is necessary to improve the safety and optimize the treatment effect of the surgery. For optical fiber laser ablation surgery using a 980nm infrared laser, this article applies CaWO<sub>4</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> nanoparticles to adhere to the end of the optical fiber. The 980nm laser excites the CaWO<sub>4</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> nanoparticles to generate up-conversion green light. The green fluorescence peak ratio is used for real-time measurement of the temperature at the optical fiber's end, which corresponds to the temperature of the heated tissue. This article designs the optical path, calibrates the relationship between the fluorescence peak ratio and temperature, and obtains a fitting expression for the temperature and fluorescence peak ratio. This temperature sensor is expected to be used for automatic temperature measurement in optical fiber laser ablation surgery of biological tissues. Compared to existing technologies, this experiment uses a 980nm laser for ablation while simultaneously excited the fluorescence at the end of the optical fiber with this wavelength.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3053049
Primary Topic
Solid State Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time automatic temperature monitoring in fiber laser ablation of biological tissue surgery

Yantang Huang, Wenwei Yu, Ruijia Zhang, Yujing Chen et al.
Solid State Laser Technologies
article

Real-time automatic temperature monitoring in fiber laser ablation of biological tissue surgery

Yantang Huang, Wenwei Yu, Ruijia Zhang, Yujing Chen, Qiaoyun Yang
article en

Abstract

Real-time temperature monitoring during fiber laser ablation surgery on biological tissues is necessary to improve the safety and optimize the treatment effect of the surgery. For optical fiber laser ablation surgery using a 980nm infrared laser, this article applies CaWO<sub>4</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> nanoparticles to adhere to the end of the optical fiber. The 980nm laser excites the CaWO<sub>4</sub>:Er<sup>3+</sup>/Yb<sup>3+</sup> nanoparticles to generate up-conversion green light. The green fluorescence peak ratio is used for real-time measurement of the temperature at the optical fiber's end, which corresponds to the temperature of the heated tissue. This article designs the optical path, calibrates the relationship between the fluorescence peak ratio and temperature, and obtains a fitting expression for the temperature and fluorescence peak ratio. This temperature sensor is expected to be used for automatic temperature measurement in optical fiber laser ablation surgery of biological tissues. Compared to existing technologies, this experiment uses a 980nm laser for ablation while simultaneously excited the fluorescence at the end of the optical fiber with this wavelength.

Fuzhou University (CN)
Openalex Percentile: Top 80%
Solid State Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time automatic temperature monitoring in fiber laser ablation of biological tissue surgery — Yantang Huang, Wenwei Yu, et al. · (2024) | TGRS Research Map | TGRS