Design and algorithm research of high-precision laser speed measurement system

In order to meet the challenges of extracting high precision Doppler frequencies and the low measurement accuracy in laser Doppler velocimetry systems, a high-precision laser speed measurement system based on a dual-beam dual-scattering optical path is designed. First, optical frequency shifting technology and a high-pass filter is employed in dual-beam dualscattering optical path to effectively enhance the signal-to-noise ratio. Next, an adaptive sampling algorithm is introduced to further reduce system errors and improve accuracy at low speeds. Subsequently, energy centrobaric correction method is applied for spectral calibration, resulting in accurate Doppler frequency measurement. Experimental results indicate that the system's relative measurement error is less than 0.3%, fully meeting the requirements for speed measurement in modern industries such as cable manufacturing.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3052600
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and algorithm research of high-precision laser speed measurement system

Tongqing Liao, Runfeng Hu, Y. T. Liang
Advanced Optical Sensing Technologies
article

Design and algorithm research of high-precision laser speed measurement system

Tongqing Liao, Runfeng Hu, Y. T. Liang
article en

Abstract

In order to meet the challenges of extracting high precision Doppler frequencies and the low measurement accuracy in laser Doppler velocimetry systems, a high-precision laser speed measurement system based on a dual-beam dual-scattering optical path is designed. First, optical frequency shifting technology and a high-pass filter is employed in dual-beam dualscattering optical path to effectively enhance the signal-to-noise ratio. Next, an adaptive sampling algorithm is introduced to further reduce system errors and improve accuracy at low speeds. Subsequently, energy centrobaric correction method is applied for spectral calibration, resulting in accurate Doppler frequency measurement. Experimental results indicate that the system's relative measurement error is less than 0.3%, fully meeting the requirements for speed measurement in modern industries such as cable manufacturing.

Anhui University (CN)
Affordable and clean energy
Openalex Percentile: Top 82%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.