Developing interfaces for seizure diagnosis, often challenging to detect visually, is rising. However, their effectiveness is constrained by the need for diverse and extensive databases. This study aimed to create a seizure detection methodology incorporating detailed information from each EEG channel and accounts for frequency band variations linked to the primary brain pathology leading to ICU admission, enhancing our ability to identify epilepsy onset. This study involved 460 video-electroencephalography recordings from 71 patients under monitoring. We applied signal preprocessing and conducted a numerical quantitative analysis in the frequency domain. Various machine learning algorithms were assessed for their efficacy. The k-nearest neighbours (KNN) model was the most effective in our overall sample, achieving an average F1 score of 0.76. For specific subgroups, different models showed superior performance: Decision Tree for ‘Epilepsy’ (average F1 score of 0.80) and ‘Craniencephalic Trauma’ (average F1 score of 0.84), Random Forest for ‘Cardiorespiratory Arrest’ (average F1 score of 0.89) and ‘Brain Haemorrhage’ (average F1 score of 0.84). In the categorisation of seizure types, Linear Discriminant Analysis was most effective for focal seizures (average F1 score of 0.87), KNN for generalised (average F1 score of 0.84) and convulsive seizures (average F1 score of 0.88), and logistic regression for non-convulsive seizures (average F1 score of 0.83). Our study demonstrates the potential of using classifier models based on quantified EEG data for diagnosing seizures in ICU patients. The performance of these models varies significantly depending on the underlying cause of the seizure, highlighting the importance of tailored approaches. The automation of these diagnostic tools could facilitate early seizure detection.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-12
DOI
https://doi.org/10.3390/app142411616
Citations
1
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Computing Strategies for Automatic Detection of EEG Seizures in ICU

Laura López-Viñas, José L. Ayala, Javier Pardo
1 citations
Applied Sciences
EEG and Brain-Computer Interfaces
0.34
article

Real-Time Computing Strategies for Automatic Detection of EEG Seizures in ICU

Laura López-Viñas, José L. Ayala, Javier Pardo
article en
1 citations

Abstract

Developing interfaces for seizure diagnosis, often challenging to detect visually, is rising. However, their effectiveness is constrained by the need for diverse and extensive databases. This study aimed to create a seizure detection methodology incorporating detailed information from each EEG channel and accounts for frequency band variations linked to the primary brain pathology leading to ICU admission, enhancing our ability to identify epilepsy onset. This study involved 460 video-electroencephalography recordings from 71 patients under monitoring. We applied signal preprocessing and conducted a numerical quantitative analysis in the frequency domain. Various machine learning algorithms were assessed for their efficacy. The k-nearest neighbours (KNN) model was the most effective in our overall sample, achieving an average F1 score of 0.76. For specific subgroups, different models showed superior performance: Decision Tree for ‘Epilepsy’ (average F1 score of 0.80) and ‘Craniencephalic Trauma’ (average F1 score of 0.84), Random Forest for ‘Cardiorespiratory Arrest’ (average F1 score of 0.89) and ‘Brain Haemorrhage’ (average F1 score of 0.84). In the categorisation of seizure types, Linear Discriminant Analysis was most effective for focal seizures (average F1 score of 0.87), KNN for generalised (average F1 score of 0.84) and convulsive seizures (average F1 score of 0.88), and logistic regression for non-convulsive seizures (average F1 score of 0.83). Our study demonstrates the potential of using classifier models based on quantified EEG data for diagnosing seizures in ICU patients. The performance of these models varies significantly depending on the underlying cause of the seizure, highlighting the importance of tailored approaches. The automation of these diagnostic tools could facilitate early seizure detection.

Applied SciencesVol. 14(24)
Universidad Complutense de Madrid (ES), Hospital Quirónsalud Barcelona (ES), Hospital Universitario Fundación Jiménez Díaz (ES)
Reduced inequalities
Openalex Percentile: Top 38%
EEG and Brain-Computer Interfaces
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.