Development and validation of R-HPLC method for simultaneous determination of fexofenadine HCl and paracetamol for their quantification from multiparticulate drug delivery system

Abstract In the field of pharmaceutical analysis, high-performance liquid chromatography (HPLC) is considered to be the key technique, which is one of the most efficient, quick, and easy methods for the simultaneous determination of two are more drugs. The purpose of the current study is to develop and validate the reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of Paracetamol and Fexofenadine HCl. This approach was validated by the standards and The International Conference on Harmonization (ICH), and United States Pharmacopeia (USP) were followed in the development and validation of the method. The chromatographic conditions including a mobile phase comprised of a 35:65 buffer mix and acetonitrile with a 1.0 mL min −1 flow rate were used. A thorough investigation was performed, including linearity and range, specificity, robustness, accuracy, precision, solution stability, and system suitability. The outcomes of the studies have shown that, both Active Pharmaceutical ingredients i.e., Paracetamol and Fexofenadine HCl were separated in about 7.5 min. The variation coefficient for Paracetamol and fexofenadine HCl varied between 0.9992 R 2 and 0.9983 R 2 , respectively. The devised method was proved accurate, as API recoveries in both cases of Paracetamol and Fexofenadine ranged from (99.79%, 100.72%, and 98.64%) to (99.96%, 100.64%, and 99.00%). The method's accuracy was further demonstrated by the solution stability which was 99.84% for Paracetamol, and 100.53% for Fexofenadine HCl. The suggested method for simultaneously measuring Paracetamol and Fexofenadine HCl was established, validated, and there was no evidence of any excipient interaction was observed.

Authors

Institutions

Publication Details

Journal
Acta Chromatographica
Published
2024-12-12
DOI
https://doi.org/10.1556/1326.2024.01262
Primary Topic
Herbal Medicine Research Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of R-HPLC method for simultaneous determination of fexofenadine HCl and paracetamol for their quantification from multiparticulate drug delivery system

Muhammad Hasnat, Muhammad Zaman, Muhammad Amer, Muhammad Sajid Nawaz et al.
Acta Chromatographica
Herbal Medicine Research Studies
article

Development and validation of R-HPLC method for simultaneous determination of fexofenadine HCl and paracetamol for their quantification from multiparticulate drug delivery system

Muhammad Hasnat, Muhammad Zaman, Muhammad Amer, Muhammad Sajid Nawaz, Abdulhakeem S. Alamri, Majid Alhomrani, Qurat-ul-ain Shoaib, Waqar Siddique, Kanwal Shahzadi
article en

Abstract

Abstract In the field of pharmaceutical analysis, high-performance liquid chromatography (HPLC) is considered to be the key technique, which is one of the most efficient, quick, and easy methods for the simultaneous determination of two are more drugs. The purpose of the current study is to develop and validate the reversed-phase high-performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of Paracetamol and Fexofenadine HCl. This approach was validated by the standards and The International Conference on Harmonization (ICH), and United States Pharmacopeia (USP) were followed in the development and validation of the method. The chromatographic conditions including a mobile phase comprised of a 35:65 buffer mix and acetonitrile with a 1.0 mL min −1 flow rate were used. A thorough investigation was performed, including linearity and range, specificity, robustness, accuracy, precision, solution stability, and system suitability. The outcomes of the studies have shown that, both Active Pharmaceutical ingredients i.e., Paracetamol and Fexofenadine HCl were separated in about 7.5 min. The variation coefficient for Paracetamol and fexofenadine HCl varied between 0.9992 R 2 and 0.9983 R 2 , respectively. The devised method was proved accurate, as API recoveries in both cases of Paracetamol and Fexofenadine ranged from (99.79%, 100.72%, and 98.64%) to (99.96%, 100.64%, and 99.00%). The method's accuracy was further demonstrated by the solution stability which was 99.84% for Paracetamol, and 100.53% for Fexofenadine HCl. The suggested method for simultaneously measuring Paracetamol and Fexofenadine HCl was established, validated, and there was no evidence of any excipient interaction was observed.

Acta ChromatographicaVol. 37(3)
University of Lahore (PK), Taif University (SA), University of Central Punjab (PK), Riphah International University (PK), Farooq Hospital (PK), Abasyn University (PK), University of Veterinary and Animal Sciences (PK)
Taif University
Openalex Percentile: Top 57%
Herbal Medicine Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.