Measurements and Analysis of Sound Reflections from Selected Building Façades

This paper presents a study of the effect of the type of exterior cladding material of a building façade on the amount of sound reflection. It was verified whether there is a sound field undisturbed by reflections, similar to the free field, at a distance of 3 m from the building façade. Sound reflections from three building façade structures were tested: clinker brick, mineral plaster, and hard HPL. An equal geometry of the measuring field at selected real objects was used. It was determined that the differences in sound level results measured at distances up to 2 m and more than 2 m from the building façade are lower than the −3 dB correction specified in ISO 1996-2. Significant differences were observed comparing the measured sound level values in the undisturbed sound field with the levels recorded at a distance of 3 m from the building façade. It was proposed that the results of measurements made to control the levels of permissible noise in the environment should not be subject to the −3 dB correction.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-12
DOI
https://doi.org/10.3390/app142411627
Citations
3
Primary Topic
3D Surveying and Cultural Heritage
Type
article
Field-Weighted Citation Impact
2.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements and Analysis of Sound Reflections from Selected Building Façades

Adam Zagubień, Katarzyna Wolniewicz
3 citations
Applied Sciences
3D Surveying and Cultural Heritage
2.50
article

Measurements and Analysis of Sound Reflections from Selected Building Façades

Adam Zagubień, Katarzyna Wolniewicz
article en
3 citations

Abstract

This paper presents a study of the effect of the type of exterior cladding material of a building façade on the amount of sound reflection. It was verified whether there is a sound field undisturbed by reflections, similar to the free field, at a distance of 3 m from the building façade. Sound reflections from three building façade structures were tested: clinker brick, mineral plaster, and hard HPL. An equal geometry of the measuring field at selected real objects was used. It was determined that the differences in sound level results measured at distances up to 2 m and more than 2 m from the building façade are lower than the −3 dB correction specified in ISO 1996-2. Significant differences were observed comparing the measured sound level values in the undisturbed sound field with the levels recorded at a distance of 3 m from the building façade. It was proposed that the results of measurements made to control the levels of permissible noise in the environment should not be subject to the −3 dB correction.

Applied SciencesVol. 14(24)
Koszalin University of Technology (PL)
Sustainable cities and communities
Openalex Percentile: Top 9%
3D Surveying and Cultural Heritage
2.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.