Adaptive Estimation Algorithm for Photoplethysmographic Heart Rate Based on Finite State Machine

In order to address the issue of heart rate susceptibility to motion artifacts (MAs) when extracting it from photoplethysmography (PPG) signals, a heart rate estimation algorithm based on the finite state machine (FSM) is proposed. The algorithm first applies band-pass filtering to the PPG and three-axis acceleration signals. The strength of MA is assessed based on the acceleration data. If a strong MA is detected, recursive least squares (RLS) filtering is applied; otherwise, it is omitted. Then, the signal is subjected to an empirical wavelet transform (EWT). Based on the EWT results, the current state is identified, and the corresponding spectral peak screening method is selected to estimate the heart rate. The mean absolute errors of the algorithm on 12 sets of public data and 8 sets of testing data are 0.93 and 1.76 beats per minute (bpm), respectively. The results of the experiment show that compared with other dominant algorithms, the proposed algorithm estimates heart rate with a smaller mean absolute error and can extract heart rate more effectively.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-12
DOI
https://doi.org/10.3390/app142411631
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive Estimation Algorithm for Photoplethysmographic Heart Rate Based on Finite State Machine

Yehui Bie, Dong Hai, Jun Zhong, Ting Lan
2 citations
Applied Sciences
Non-Invasive Vital Sign Monitoring
0.37
article

Adaptive Estimation Algorithm for Photoplethysmographic Heart Rate Based on Finite State Machine

Yehui Bie, Dong Hai, Jun Zhong, Ting Lan
article en
2 citations

Abstract

In order to address the issue of heart rate susceptibility to motion artifacts (MAs) when extracting it from photoplethysmography (PPG) signals, a heart rate estimation algorithm based on the finite state machine (FSM) is proposed. The algorithm first applies band-pass filtering to the PPG and three-axis acceleration signals. The strength of MA is assessed based on the acceleration data. If a strong MA is detected, recursive least squares (RLS) filtering is applied; otherwise, it is omitted. Then, the signal is subjected to an empirical wavelet transform (EWT). Based on the EWT results, the current state is identified, and the corresponding spectral peak screening method is selected to estimate the heart rate. The mean absolute errors of the algorithm on 12 sets of public data and 8 sets of testing data are 0.93 and 1.76 beats per minute (bpm), respectively. The results of the experiment show that compared with other dominant algorithms, the proposed algorithm estimates heart rate with a smaller mean absolute error and can extract heart rate more effectively.

Applied SciencesVol. 14(24)
Chinese Academy of Sciences (CN), Nanjing University of Information Science and Technology (CN), Suzhou Institute of Biomedical Engineering and Technology (CN)
Government of Jiangsu Province, National Key Research and Development Program of China
Openalex Percentile: Top 42%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Adaptive Estimation Algorithm for Photoplethysmographic Heart Rate Based on Finite State Machine — Yehui Bie, Dong Hai, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS