Tympanic Pre-Operative Electrically Evoked Auditory Late Response (TympEALR) as an Alternative to Trans-Tympanic Tests Using Anesthesia in Cochlear Implant Candidacy

<b>Background/Objectives</b>: Before a cochlear implant is considered, patients undergo various audiological tests to assess their suitability. One key test measures the auditory brainstem response (ABR) to acoustic stimuli. However, in some cases, even with maximum sound stimulation, no response is detected. <b>Methods</b>: The promontory test involves electrical stimulation near the auditory nerve, allowing patients to associate the sensation. Ideally, the electrode is placed in the middle ear after opening the eardrum. This method, along with trans-tympanic electrically evoked ABR in local anesthesia (LA-TT-EABR) and the cortical equivalent (LA-TT-EALR), helps assess the auditory nerve's existence and excitability. The TympEALR test, utilizing a "tympanic LA-TT-EALR", provides an alternative measurement. Previous research has shown the possibility of deriving brainstem and cortical potentials through trans-tympanic electrical stimulation, allowing for objective assessment of the auditory nerve's integrity and potentially objectifying patient sensations. <b>Results:</b> Sixteen patients have been tested using TympEALR. In seven of these, we found a positive response. The morphology was similar to other electrically evoked cortical auditory responses (EALR), e.g., using cochlear implants or trans-tympanic stimulation electrodes. We observed a higher influence of electrical artifacts than in other EALRs. <b>Conclusions</b>: TympEALR showed positive results in nearly half of the study participants, potentially avoiding invasive procedures. TympEALR can be a valuable alternative to trans-tympanic methods. More research is needed to determine if a negative result suggests against cochlear implantation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-12-12
DOI
https://doi.org/10.3390/jcm13247573
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tympanic Pre-Operative Electrically Evoked Auditory Late Response (TympEALR) as an Alternative to Trans-Tympanic Tests Using Anesthesia in Cochlear Implant Candidacy

Daniel Polterauer, Florian Simon, Maike Neuling
Journal of Clinical Medicine
Hearing Loss and Rehabilitation
article

Tympanic Pre-Operative Electrically Evoked Auditory Late Response (TympEALR) as an Alternative to Trans-Tympanic Tests Using Anesthesia in Cochlear Implant Candidacy

Daniel Polterauer, Florian Simon, Maike Neuling
article en

Abstract

<b>Background/Objectives</b>: Before a cochlear implant is considered, patients undergo various audiological tests to assess their suitability. One key test measures the auditory brainstem response (ABR) to acoustic stimuli. However, in some cases, even with maximum sound stimulation, no response is detected. <b>Methods</b>: The promontory test involves electrical stimulation near the auditory nerve, allowing patients to associate the sensation. Ideally, the electrode is placed in the middle ear after opening the eardrum. This method, along with trans-tympanic electrically evoked ABR in local anesthesia (LA-TT-EABR) and the cortical equivalent (LA-TT-EALR), helps assess the auditory nerve's existence and excitability. The TympEALR test, utilizing a "tympanic LA-TT-EALR", provides an alternative measurement. Previous research has shown the possibility of deriving brainstem and cortical potentials through trans-tympanic electrical stimulation, allowing for objective assessment of the auditory nerve's integrity and potentially objectifying patient sensations. <b>Results:</b> Sixteen patients have been tested using TympEALR. In seven of these, we found a positive response. The morphology was similar to other electrically evoked cortical auditory responses (EALR), e.g., using cochlear implants or trans-tympanic stimulation electrodes. We observed a higher influence of electrical artifacts than in other EALRs. <b>Conclusions</b>: TympEALR showed positive results in nearly half of the study participants, potentially avoiding invasive procedures. TympEALR can be a valuable alternative to trans-tympanic methods. More research is needed to determine if a negative result suggests against cochlear implantation.

Journal of Clinical MedicineVol. 13(24)
München Klinik (DE), Ludwig-Maximilians-Universität München (DE)
Ludwig-Maximilians-Universität München, MED-EL Medical Electronics
Openalex Percentile: Top 76%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.