ANALYSIS OF CLINICAL AND ECHOCARDIOGRAPHIC OUTCOMES IN PATIENTS UNDER 70 YEARS OF AGE WHO UNDERWENT BIOLOGICAL AORTIC VALVE REPLACEMENT: INSPIRIS RESILIA VS. PERIMOUNT MAGNA EASE

Background: The INSPIRIS-RESILIA-aortic-prosthesis, made from bovine-pericardial- tissue, features an expandable-stent for easier future TAVI and anti-calcification-properties. Mid-term-outcome reports are still insufficient. This study compares midterm, clinical, and echocardiographic performance between patients implanted with the INSPIRIS-valve and those with the CE-Perimount-MAGNA-EASE-valve. Methods: This study is a retrospective-single-centre study. All patients received biological- prostheses, with or without additional procedures, through full-sternotomy, and follow-up included survival, complications, and hospital stay length. The primary outcome was all-cause- mortality one year post-AVR, with secondary-outcomes including gradients, EF, reintervention rates, and postoperative complications. Data were analyzed using descriptive statistics, and PS- matching was used to adjust for baseline differences. Results: We included 300 patients, who were implanted with INSPIRIS (n=52), or ME (n=248) between January 2018 and May 2023. After matching each group included 52 patients. The INSPIRIS-group consisted of younger patients with fewer comorbidities compared to the ME-group, which had higher rates of PAD, preoperative AF, and PTCA. Postoperative- outcomes showed the ME-group had higher transfusion rates (INSPIRIS: 46,1% vs ME: 69,2%, P = 0.017), longer CPB-times (INSPIRIS 93 ± 22, ME 109,51 ± 35,05 P=0,004), and a higher, but not statistically significant, reoperation-rate. Mid-term-results showed no significant difference in survival, SVD, or transvalvular-mean-gradient at 1 year (INSPIRIS 11,3 ± 3,56, ME 11,2 ± 4,1, P=0,9), and 3 years (INSPIRIS 12,9 ± 3,7, ME 12,9 ± 3,6, P=0,7). Conclusion: Surgical-AVR using the INSPIRIS-valve exhibited comparable safety and satisfactory mid-term-outcomes, with hemodynamic performance similar to the ME-valve. This study demonstrates favorable clinical results and good hemodynamics at 3 years.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Medicine
Published
2024-12-01
DOI
https://doi.org/10.2459/01.jcm.0001096536.31457.4c
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF CLINICAL AND ECHOCARDIOGRAPHIC OUTCOMES IN PATIENTS UNDER 70 YEARS OF AGE WHO UNDERWENT BIOLOGICAL AORTIC VALVE REPLACEMENT: INSPIRIS RESILIA VS. PERIMOUNT MAGNA EASE

Vito Giovanni Ruggieri, Antonio D’Errico Ramirez, Ibrahim Alqdeimat, Gabriel Saiydoun et al.
Journal of Cardiovascular Medicine
Cardiac Valve Diseases and Treatments
article

ANALYSIS OF CLINICAL AND ECHOCARDIOGRAPHIC OUTCOMES IN PATIENTS UNDER 70 YEARS OF AGE WHO UNDERWENT BIOLOGICAL AORTIC VALVE REPLACEMENT: INSPIRIS RESILIA VS. PERIMOUNT MAGNA EASE

Vito Giovanni Ruggieri, Antonio D’Errico Ramirez, Ibrahim Alqdeimat, Gabriel Saiydoun, E Nassar
article en

Abstract

Background: The INSPIRIS-RESILIA-aortic-prosthesis, made from bovine-pericardial- tissue, features an expandable-stent for easier future TAVI and anti-calcification-properties. Mid-term-outcome reports are still insufficient. This study compares midterm, clinical, and echocardiographic performance between patients implanted with the INSPIRIS-valve and those with the CE-Perimount-MAGNA-EASE-valve. Methods: This study is a retrospective-single-centre study. All patients received biological- prostheses, with or without additional procedures, through full-sternotomy, and follow-up included survival, complications, and hospital stay length. The primary outcome was all-cause- mortality one year post-AVR, with secondary-outcomes including gradients, EF, reintervention rates, and postoperative complications. Data were analyzed using descriptive statistics, and PS- matching was used to adjust for baseline differences. Results: We included 300 patients, who were implanted with INSPIRIS (n=52), or ME (n=248) between January 2018 and May 2023. After matching each group included 52 patients. The INSPIRIS-group consisted of younger patients with fewer comorbidities compared to the ME-group, which had higher rates of PAD, preoperative AF, and PTCA. Postoperative- outcomes showed the ME-group had higher transfusion rates (INSPIRIS: 46,1% vs ME: 69,2%, P = 0.017), longer CPB-times (INSPIRIS 93 ± 22, ME 109,51 ± 35,05 P=0,004), and a higher, but not statistically significant, reoperation-rate. Mid-term-results showed no significant difference in survival, SVD, or transvalvular-mean-gradient at 1 year (INSPIRIS 11,3 ± 3,56, ME 11,2 ± 4,1, P=0,9), and 3 years (INSPIRIS 12,9 ± 3,7, ME 12,9 ± 3,6, P=0,7). Conclusion: Surgical-AVR using the INSPIRIS-valve exhibited comparable safety and satisfactory mid-term-outcomes, with hemodynamic performance similar to the ME-valve. This study demonstrates favorable clinical results and good hemodynamics at 3 years.

Journal of Cardiovascular MedicineVol. 25(Supplement 1Supplement 1)
Sorbonne Université (FR), Centre Hospitalier Universitaire de Reims (FR), Pitié-Salpêtrière Hospital (FR), Université de Reims Champagne-Ardenne (FR)
Good health and well-being
Openalex Percentile: Top 58%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.