MINIMALLY INVASIVE AORTIC VALVE SURGERY WITH VENOUS WALL-LESS CANNULAS: PERFORMANCES AND SAFETY PROFILE

Introduction: Techniques for venous cannulation during aortic minimally invasive surgery (MICS) evolved significantly. Aim of this study is to report the institutional experience with virtually wall-less venous cannulas during MICS aortic surgery. Methods: Transfemoral venous cannulation with Smart cannulas was performed in consecutive patients undergoing aortic MICS (isolated or in combination with other procedures). Target venous flow drainage (2.4 L/mq, Cardiac Index) and maximal suction performance without vacuum assistance were measured along with complications. Results: Since 2017, the Smartcannula was successfully positioned in all 75 patients (65.3 ± 11.8 years, 56 males) undergoing aortic MICS. The size measured 680 mm in length was adopted in all but two patients, who received the 530 mm Smartcannula. Regarding the surgical access, it was a superior mini-sternotomy in 75 patients (57 AVR, 10 bio-Bentall, 8 isolated ascending aorta and hemi-arch replacement). For a body height of 169.22 ± 24.83 cm and a body weight of 80.55 ± 15.21 kg, the calculated body surface area was 1.93 ± 0.22 mq. Expected target flow of 4.63 ± 0.53, whereas the achieved flow accounted for 5.85 ± 0.88 l/min (increase of 19.79%, in respect to target flow) without adopting vacuum, in all cases. Conclusion: The performance of self-expanding smart cannulas for venous drainage during aortic MICS proved to be extremely satisfactory, with a high safety profile. The drainage is optimal without vacuum in this setting, suggesting a steady superior flow over traditional rigid wall cannulas and confirming the efficacy during their routinary use.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Medicine
Published
2024-12-01
DOI
https://doi.org/10.2459/01.jcm.0001096484.98582.6f
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MINIMALLY INVASIVE AORTIC VALVE SURGERY WITH VENOUS WALL-LESS CANNULAS: PERFORMANCES AND SAFETY PROFILE

Tiziano Torre, Francesca Toto, Mirko Muretti, Stefanos Demertzis et al.
Journal of Cardiovascular Medicine
Cardiac Valve Diseases and Treatments
article

MINIMALLY INVASIVE AORTIC VALVE SURGERY WITH VENOUS WALL-LESS CANNULAS: PERFORMANCES AND SAFETY PROFILE

Tiziano Torre, Francesca Toto, Mirko Muretti, Stefanos Demertzis, Alberto Pozzoli, Enrico Ferrari, M. Schraemli
article en

Abstract

Introduction: Techniques for venous cannulation during aortic minimally invasive surgery (MICS) evolved significantly. Aim of this study is to report the institutional experience with virtually wall-less venous cannulas during MICS aortic surgery. Methods: Transfemoral venous cannulation with Smart cannulas was performed in consecutive patients undergoing aortic MICS (isolated or in combination with other procedures). Target venous flow drainage (2.4 L/mq, Cardiac Index) and maximal suction performance without vacuum assistance were measured along with complications. Results: Since 2017, the Smartcannula was successfully positioned in all 75 patients (65.3 ± 11.8 years, 56 males) undergoing aortic MICS. The size measured 680 mm in length was adopted in all but two patients, who received the 530 mm Smartcannula. Regarding the surgical access, it was a superior mini-sternotomy in 75 patients (57 AVR, 10 bio-Bentall, 8 isolated ascending aorta and hemi-arch replacement). For a body height of 169.22 ± 24.83 cm and a body weight of 80.55 ± 15.21 kg, the calculated body surface area was 1.93 ± 0.22 mq. Expected target flow of 4.63 ± 0.53, whereas the achieved flow accounted for 5.85 ± 0.88 l/min (increase of 19.79%, in respect to target flow) without adopting vacuum, in all cases. Conclusion: The performance of self-expanding smart cannulas for venous drainage during aortic MICS proved to be extremely satisfactory, with a high safety profile. The drainage is optimal without vacuum in this setting, suggesting a steady superior flow over traditional rigid wall cannulas and confirming the efficacy during their routinary use.

Journal of Cardiovascular MedicineVol. 25(Supplement 1Supplement 1)
Epatocentro Ticino (CH)
Openalex Percentile: Top 58%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.