ONE YEAR OUTCOME OF A NOVEL SELF-EXPANDING TAVR IMPLANTED IN A SURGICAL SETTING

Background and Aim: Transcatheter aortic valve replacement (TAVR) represents the ideal alternative for aortic valve disease in elderly patients. The Navitor valve, a third generation self- expanding valve system from the Portico series, was designed to minimize TAVR complications. This study aimed to evaluate the outcome of patients with at least 12 months follow-up, undergone TAVR using Navitor valve. Methods: From September 2021 to August 2023, seventeen patients (age 85,7±3,7 y.o, 17,6% male) with severe aortic valve disease underwent transcatheter treatment. Results: A CT scan anatomic evaluation was performed in all patients (perimetral annulus 72,8 [68,3-77,8], annulus area 3,6 [3,3-4,1], maximum annulus size 26 [23,5-28], STJ 27 [26-30]). 15 patients required pre-dilation, using Osypka balloon. Size of implanted valve was generally high (median 27 [25-27]). In-hospital mortality was observed in 2 patients. Other adverse events included: 1 vascular complication (pseudoaneurysm), 2 permanent pacemaker implantations. No pericardial effusion or stroke occurred over a median length of stay of 3 days. At 1 year, no signs of structural valve degeneration were observed, with a mean gradient of 6,5 (6-9) mmHg, peak gradient of 11 (10-16) mmHg, valve area of 1,7 (1,6-1,9) cmq and no decline in LVEF. A total of 5 mild PVL were observed without clinical implications. No late clinical events occurred. Conclusions: TAVR with Navitor valve provides excellent short term results and good hemodynamic performance over the first year after implant. The acceptable rate of PVL and PMK implantation might represent an interesting finding to be investigated in larger studies.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Medicine
Published
2024-12-01
DOI
https://doi.org/10.2459/01.jcm.0001096328.57872.7b
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ONE YEAR OUTCOME OF A NOVEL SELF-EXPANDING TAVR IMPLANTED IN A SURGICAL SETTING

Antonio Giovanni Cammardella, Carla Manzara, Amedeo Pergolini, Edoardo Rosario de Natale et al.
Journal of Cardiovascular Medicine
Shoulder and Clavicle Injuries
article

ONE YEAR OUTCOME OF A NOVEL SELF-EXPANDING TAVR IMPLANTED IN A SURGICAL SETTING

Antonio Giovanni Cammardella, Carla Manzara, Amedeo Pergolini, Edoardo Rosario de Natale, Federico Ranocchi, Marco Russo, Massimo Chello, Chiara Ferrisi, Flavia Belloni, G. Luzi
article en

Abstract

Background and Aim: Transcatheter aortic valve replacement (TAVR) represents the ideal alternative for aortic valve disease in elderly patients. The Navitor valve, a third generation self- expanding valve system from the Portico series, was designed to minimize TAVR complications. This study aimed to evaluate the outcome of patients with at least 12 months follow-up, undergone TAVR using Navitor valve. Methods: From September 2021 to August 2023, seventeen patients (age 85,7±3,7 y.o, 17,6% male) with severe aortic valve disease underwent transcatheter treatment. Results: A CT scan anatomic evaluation was performed in all patients (perimetral annulus 72,8 [68,3-77,8], annulus area 3,6 [3,3-4,1], maximum annulus size 26 [23,5-28], STJ 27 [26-30]). 15 patients required pre-dilation, using Osypka balloon. Size of implanted valve was generally high (median 27 [25-27]). In-hospital mortality was observed in 2 patients. Other adverse events included: 1 vascular complication (pseudoaneurysm), 2 permanent pacemaker implantations. No pericardial effusion or stroke occurred over a median length of stay of 3 days. At 1 year, no signs of structural valve degeneration were observed, with a mean gradient of 6,5 (6-9) mmHg, peak gradient of 11 (10-16) mmHg, valve area of 1,7 (1,6-1,9) cmq and no decline in LVEF. A total of 5 mild PVL were observed without clinical implications. No late clinical events occurred. Conclusions: TAVR with Navitor valve provides excellent short term results and good hemodynamic performance over the first year after implant. The acceptable rate of PVL and PMK implantation might represent an interesting finding to be investigated in larger studies.

Journal of Cardiovascular MedicineVol. 25(Supplement 1Supplement 1)
Università Campus Bio-Medico (IT), Ospedale di Santo Spirito (IT)
Openalex Percentile: Top 66%
Shoulder and Clavicle Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.