Current Harmonics Suppression of Six-Phase Permanent-Magnet Synchronous Motor Drives Using Back-Electromotive Force Harmonics Compensation

This paper investigates a back-electromotive force (EMF) harmonic compensation strategy for six-phase permanent-magnet synchronous motors (PMSMs) to reduce current harmonics and improve system performance. Ideally, the back-EMF waveform should be perfectly sinusoidal. However, manufacturing imperfections such as suboptimal magnetic circuit design, uneven winding distribution, and mechanical eccentricity introduce low-order spatial harmonics, particularly the 5th, 7th, 11th, and 13th orders, which distort the back-EMF, increase current harmonics, complicate control, and reduce efficiency. To address these issues, this study proposes a compensation strategy utilizing common-mode and differential-mode current control. By injecting the 6th and 12th harmonics into the decoupled voltage commands along the d-axis and q-axis, the strategy significantly reduces current harmonic distortion. Experimental validation was conducted using a TMS320F28386D microcontroller, which controlled dual inverters via PWM signals and processed real-time current feedback. Rotor position feedback was provided by a resolver to ensure precise and responsive motor control. At a rotational speed of 900 rpm, with a peak phase current Im of 200 A and an IGBT switching frequency of 10 kHz, the phase-a current total harmonic distortion (THD) was reduced from 11.86% (without compensation) to 6.83% (with compensation). This study focused on mitigating harmonics below the 14th order. The experimental results demonstrate that the proposed back-EMF harmonic compensation strategy effectively minimizes current THD, highlighting its potential for improving the performance and efficiency of multi-phase motor systems.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-12-12
DOI
https://doi.org/10.3390/en17246280
Citations
3
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current Harmonics Suppression of Six-Phase Permanent-Magnet Synchronous Motor Drives Using Back-Electromotive Force Harmonics Compensation

Cheng-Ting Tsai, Cheng-Tsung Lin, Yu‐Ting Lin, Jonq-Chin Hwang et al.
3 citations
Energies
Multilevel Inverters and Converters
0.63
article

Current Harmonics Suppression of Six-Phase Permanent-Magnet Synchronous Motor Drives Using Back-Electromotive Force Harmonics Compensation

Cheng-Ting Tsai, Cheng-Tsung Lin, Yu‐Ting Lin, Jonq-Chin Hwang, Po-Sheng Huang
article en
3 citations

Abstract

This paper investigates a back-electromotive force (EMF) harmonic compensation strategy for six-phase permanent-magnet synchronous motors (PMSMs) to reduce current harmonics and improve system performance. Ideally, the back-EMF waveform should be perfectly sinusoidal. However, manufacturing imperfections such as suboptimal magnetic circuit design, uneven winding distribution, and mechanical eccentricity introduce low-order spatial harmonics, particularly the 5th, 7th, 11th, and 13th orders, which distort the back-EMF, increase current harmonics, complicate control, and reduce efficiency. To address these issues, this study proposes a compensation strategy utilizing common-mode and differential-mode current control. By injecting the 6th and 12th harmonics into the decoupled voltage commands along the d-axis and q-axis, the strategy significantly reduces current harmonic distortion. Experimental validation was conducted using a TMS320F28386D microcontroller, which controlled dual inverters via PWM signals and processed real-time current feedback. Rotor position feedback was provided by a resolver to ensure precise and responsive motor control. At a rotational speed of 900 rpm, with a peak phase current Im of 200 A and an IGBT switching frequency of 10 kHz, the phase-a current total harmonic distortion (THD) was reduced from 11.86% (without compensation) to 6.83% (with compensation). This study focused on mitigating harmonics below the 14th order. The experimental results demonstrate that the proposed back-EMF harmonic compensation strategy effectively minimizes current THD, highlighting its potential for improving the performance and efficiency of multi-phase motor systems.

EnergiesVol. 17(24)
National Taiwan University of Science and Technology (TW)
Affordable and clean energy
Openalex Percentile: Top 30%
Multilevel Inverters and Converters
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Current Harmonics Suppression of Six-Phase Permanent-Magnet Synchronous Motor Drives Using Back-Electromotive Force Harmonics Compensation — Cheng-Ting Tsai, Cheng-Tsung Lin, et al. · Energies (2024) | TGRS Research Map | TGRS