Failure analysis of external thread insulated live joint for metering in gas transmission station

An insulating joint is an important accessory of a cathodic protection system and plays an important role in the safe operation of a pipeline. In this paper, failure analysis is carried out on the fracture cause of an insulated live joint with an external thread. This type of insulated joint is an assembly and the middle part is connected by the butt welding method. The failed insulated live joint with external thread breaks at the welded joint, and the failure cause is closely related to the incomplete welding of the whole circle at the root and the poor fusion quality of the weld. In addition, the welded root of the intact external thread-insulated live joint submitted for inspection is not welded through. Relevant standards are used to evaluate the service capability of the insulated joint with defects, and the suitability evaluation results are unacceptable under operating pressure and design pressure. At the same time, considering the poor fusion quality of the weld, it is recommended to choose the machine for equipment replacement.

Authors

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3050783
Primary Topic
Fatigue and fracture mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure analysis of external thread insulated live joint for metering in gas transmission station

Qiliang Lu
Fatigue and fracture mechanics
article

Failure analysis of external thread insulated live joint for metering in gas transmission station

Qiliang Lu
article en

Abstract

An insulating joint is an important accessory of a cathodic protection system and plays an important role in the safe operation of a pipeline. In this paper, failure analysis is carried out on the fracture cause of an insulated live joint with an external thread. This type of insulated joint is an assembly and the middle part is connected by the butt welding method. The failed insulated live joint with external thread breaks at the welded joint, and the failure cause is closely related to the incomplete welding of the whole circle at the root and the poor fusion quality of the weld. In addition, the welded root of the intact external thread-insulated live joint submitted for inspection is not welded through. Relevant standards are used to evaluate the service capability of the insulated joint with defects, and the suitability evaluation results are unacceptable under operating pressure and design pressure. At the same time, considering the poor fusion quality of the weld, it is recommended to choose the machine for equipment replacement.

Affordable and clean energy
Openalex Percentile: Top 75%
Fatigue and fracture mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Failure analysis of external thread insulated live joint for metering in gas transmission station — Qiliang Lu · (2024) | TGRS Research Map | TGRS