Research on liquid cooling and heat dissipation performance of lithium batteries for energy storage
Thermal management is key to ensuring the continued safe operation of energy storage systems. Good thermal management can ensure that the energy storage battery works at the right temperature, thereby improving its charging and discharging efficiency. The 280Ah lithium iron phosphate battery for was selected as the research object, and the numerical simulation model of the liquid-cooled plate battery pack was studied. Compared with the working condition with the discharge rate of 1C, under the condition of 2C, the T<sub>min</sub> of the battery pack does not change seriously at the same speed, and the maximum temperature increases by about 2.76°C.
Authors
- Lulu Wang (ORCID: https://orcid.org/0009-0004-5328-8420)
Institutions
- North China Electric Power University (CN)
- China Datang Corporation (China) (CN)
- China Electric Power Research Institute
Publication Details
- Published
- 2024-12-12
- DOI
- https://doi.org/10.1117/12.3050905
- Primary Topic
- Power Systems and Renewable Energy
- Type
- article
- Field-Weighted Citation Impact
- 0.00