Simulation study on the influence factors of dynamic capacitance of SF6 circuit breaker during breaking

SF<sub>6</sub> circuit breakers are widely used in power system. Due to the accumulation of arc ablative effect, the arc contact state of SF<sub>6</sub> circuit breakers deteriorates continuously, which will lead to the decline of the insulation grade and breaking capacity of the break chamber. The dynamic capacitance simulation model of SF<sub>6</sub> circuit breaker was established, and the dynamic capacitance influencing factors were studied. Simulation study of the static arc contact length, static arc contact ablation angle, dynamic arc contact inner diameter and arc contact surface fluoride on the dynamic capacitance characteristics. The establishment of a comprehensive consideration of deterioration caused by various changes in the contact simulation model and test results for comparison, the results show that with the increase in the degree of comprehensive deterioration, the dynamic capacitance curve just split point travel down, just split point capacitance rise, completely split point capacitance is unchanged, the rule of change and the test results are consistent with the validity of the contact deterioration model.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3050466
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation study on the influence factors of dynamic capacitance of SF6 circuit breaker during breaking

Feiyue Ma, C. Xu, Beiyang Liu, Bo Niu et al.
Vacuum and Plasma Arcs
article

Simulation study on the influence factors of dynamic capacitance of SF6 circuit breaker during breaking

Feiyue Ma, C. Xu, Beiyang Liu, Bo Niu, Yu Wang, Hui Ni
article en

Abstract

SF<sub>6</sub> circuit breakers are widely used in power system. Due to the accumulation of arc ablative effect, the arc contact state of SF<sub>6</sub> circuit breakers deteriorates continuously, which will lead to the decline of the insulation grade and breaking capacity of the break chamber. The dynamic capacitance simulation model of SF<sub>6</sub> circuit breaker was established, and the dynamic capacitance influencing factors were studied. Simulation study of the static arc contact length, static arc contact ablation angle, dynamic arc contact inner diameter and arc contact surface fluoride on the dynamic capacitance characteristics. The establishment of a comprehensive consideration of deterioration caused by various changes in the contact simulation model and test results for comparison, the results show that with the increase in the degree of comprehensive deterioration, the dynamic capacitance curve just split point travel down, just split point capacitance rise, completely split point capacitance is unchanged, the rule of change and the test results are consistent with the validity of the contact deterioration model.

North China Electric Power University (CN), State Grid Corporation of China (China) (CN), Wuhan University (CN), China Electric Power Research Institute
Openalex Percentile: Top 79%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.