Analysis of voltage variation and unbalance of 10kV line break in a power distribution network

Distribution network’s line break is a typical fault type of distribution network. Generally speaking, line breakage faults can occur at any position of the line, which can be roughly divided into power supply side, middle section, and load side. Generally speaking, after a single-phase line break occurs, the relative ground voltage of the line break phase increases, while the two-phase voltage of the phase without line break decreases. However, the location of the line break point is closer to the power side or the load side, and the voltage changes between the fault phase and the non fault phase are not exactly the same. This paper analyzes the principle of neutral point voltage displacement and voltage asymmetry caused by single-phase line break in power distribution system with neutral non-effectively grounded through formula derivation. Finally, a typical case is analyzed to investigate the voltage offset caused by single-phase line break.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3050239
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of voltage variation and unbalance of 10kV line break in a power distribution network

Zhiyu Zhao, Yuan Ma, Weilin Liu, Tianle Liang et al.
Power Systems Fault Detection
article

Analysis of voltage variation and unbalance of 10kV line break in a power distribution network

Zhiyu Zhao, Yuan Ma, Weilin Liu, Tianle Liang, Haiping Wei
article en

Abstract

Distribution network’s line break is a typical fault type of distribution network. Generally speaking, line breakage faults can occur at any position of the line, which can be roughly divided into power supply side, middle section, and load side. Generally speaking, after a single-phase line break occurs, the relative ground voltage of the line break phase increases, while the two-phase voltage of the phase without line break decreases. However, the location of the line break point is closer to the power side or the load side, and the voltage changes between the fault phase and the non fault phase are not exactly the same. This paper analyzes the principle of neutral point voltage displacement and voltage asymmetry caused by single-phase line break in power distribution system with neutral non-effectively grounded through formula derivation. Finally, a typical case is analyzed to investigate the voltage offset caused by single-phase line break.

State Grid Corporation of China (China) (CN), Inner Mongolia Electric Power (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.