Design and development of testing device for medical microwave therapeutic apparatus

Microwave technology has been widely used in clinical applications at home and abroad, especially in eliminating a variety of inflammation, relieving patients' pain, promoting blood circulation has shown unique therapeutic effects, and has been widely recognized by the medical community. Inaccurate output power and frequency of the instrument, poor stability, excessive harmonic frequency, etc., which affect the treatment effect and generate interference signals in the surrounding environment. Therefore, the design and development of a testing device, according to the use of the instrument, regular performance evaluation and maintenance of the equipment is of great significance for ensuring the safety of microwave equipment and treatment effect, and preventing adverse events.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1117/12.3055386
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and development of testing device for medical microwave therapeutic apparatus

Junjie Jiang, Xinyu Dong, Rui Gao, Ming Tian
Wireless Body Area Networks
article

Design and development of testing device for medical microwave therapeutic apparatus

Junjie Jiang, Xinyu Dong, Rui Gao, Ming Tian
article en

Abstract

Microwave technology has been widely used in clinical applications at home and abroad, especially in eliminating a variety of inflammation, relieving patients' pain, promoting blood circulation has shown unique therapeutic effects, and has been widely recognized by the medical community. Inaccurate output power and frequency of the instrument, poor stability, excessive harmonic frequency, etc., which affect the treatment effect and generate interference signals in the surrounding environment. Therefore, the design and development of a testing device, according to the use of the instrument, regular performance evaluation and maintenance of the equipment is of great significance for ensuring the safety of microwave equipment and treatment effect, and preventing adverse events.

Tianjin Institute of Metrological Supervision Testing (CN)
Openalex Percentile: Top 79%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.