Error Verification of UV Integrated Exposure Due to Light Receiving Surface Spacing Using Optical Simulation and Application to the Development of UV Sterilization Equipment

Due to the prevalence of infectious diseases caused by viruses and bacteria, UV sterilization has been attracting attention. Since UV is invisible, the repeated prototyping, measurement, and sterilization testing involved in the product development is both time-consuming and costly. This paper discusses the effect of the light receiving surface spacing on the results of the analysis of UV integrated light exposure, and shows that the error increases as the light receiving surface spacing increases. We calculated the UV integrated light exposure of the water sterilizer, and found that, based on a 5 mm light receiving surface spacing, the error was 0.17% when the light receiving surface spacing was 100 mm and the reflectance of the component was 90%, and the error was 6.03% when the reflectance of the component was 30%. Next, using the average of the irradiance at three locations on the light receiving surface to calculate the UV integrated light exposure, we found that the maximum error was 0.51% when the reflectance of the component was 90%, and the maximum error was 23.89% when the reflectance of the component was 30%.We therefore recommend examining the analysis results by setting multiple patterns of light receiving surface spacing for the analytical model and performing optical simulations with light receiving surface spacing where the errors in the analytical values and the computational resources are acceptable. In addition, we describe the process of applying this analysis method to the development of UV sterilization equipment.

Authors

Institutions

Publication Details

Journal
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
Published
2024-12-12
DOI
https://doi.org/10.2150/jieij.24000639
Primary Topic
Digital Imaging in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Error Verification of UV Integrated Exposure Due to Light Receiving Surface Spacing Using Optical Simulation and Application to the Development of UV Sterilization Equipment

Masatoshi Tanaka
JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN
Digital Imaging in Medicine
article

Error Verification of UV Integrated Exposure Due to Light Receiving Surface Spacing Using Optical Simulation and Application to the Development of UV Sterilization Equipment

Masatoshi Tanaka
article en

Abstract

Due to the prevalence of infectious diseases caused by viruses and bacteria, UV sterilization has been attracting attention. Since UV is invisible, the repeated prototyping, measurement, and sterilization testing involved in the product development is both time-consuming and costly. This paper discusses the effect of the light receiving surface spacing on the results of the analysis of UV integrated light exposure, and shows that the error increases as the light receiving surface spacing increases. We calculated the UV integrated light exposure of the water sterilizer, and found that, based on a 5 mm light receiving surface spacing, the error was 0.17% when the light receiving surface spacing was 100 mm and the reflectance of the component was 90%, and the error was 6.03% when the reflectance of the component was 30%. Next, using the average of the irradiance at three locations on the light receiving surface to calculate the UV integrated light exposure, we found that the maximum error was 0.51% when the reflectance of the component was 90%, and the maximum error was 23.89% when the reflectance of the component was 30%.We therefore recommend examining the analysis results by setting multiple patterns of light receiving surface spacing for the analytical model and performing optical simulations with light receiving surface spacing where the errors in the analytical values and the computational resources are acceptable. In addition, we describe the process of applying this analysis method to the development of UV sterilization equipment.

JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPANVol. 109(R1)
Fukuoka Industrial Technology Center (JP)
Openalex Percentile: Top 65%
Digital Imaging in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Error Verification of UV Integrated Exposure Due to Light Receiving Surface Spacing Using Optical Simulation and Application to the Development of UV Sterilization Equipment — Masatoshi Tanaka · JOURNAL OF THE ILLUMINATING ENGINEERING INSTITUTE OF JAPAN (2024) | TGRS Research Map | TGRS