TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas

This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention. Samples undergoing TEVAR showed a higher ascending systolic pressure post-intervention than OAR (TEVAR: 137±9mmHg vs OAR: 126±6mmHg, p=0.017). After the intervention, a significant discrepancy in the mean pressure differences between the ascending and descending aorta ΔP was observed (TEVAR: 9±3mmHg vs OAR: 1±2mmHg, p=0.004). Input impedance at zero frequency, approximating Windkessel resistance, was higher for TEVAR than for OAR (TEVAR: 1.78±0.04 vs OAR: 1.66±0.03mmHgs/ml, p=0.004). A correlation was found between the resistance and the negative peak of the time-normalized wave intensity analysis (Kendall's coefficient τ=-0.35 and p=0.023). Another correlation was observed between resistance and ΔP (τ=0.51, p=0.001). Looking at the replication of heart rate and stroke volume over the course of the study, the observed differences can largely be attributed to the type of intervention. The results suggest that TEVAR has adverse effects compared to OAR, particularly with regard to left ventricular afterload. Clinicians should consider the possibility of increased afterload and altered wave dynamics when deciding on TEVAR, particularly in patients with pre-existing impaired cardiovascular conditions.

Authors

Institutions

Publication Details

Journal
Acta Biomaterialia
Published
2024-12-12
DOI
https://doi.org/10.1016/j.actbio.2024.12.019
Citations
4
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas

Gerhard A. Holzapfel, Peter Regitnig, Gerhard Sommer, Heinrich Mächler et al.
4 citations
Acta Biomaterialia
Aortic Disease and Treatment Approaches
1.68
article

TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas

Gerhard A. Holzapfel, Peter Regitnig, Gerhard Sommer, Heinrich Mächler, Emmanouil Agrafiotis, Günther Laufer, Masoud Yusefi
article en
4 citations

Abstract

This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention. Samples undergoing TEVAR showed a higher ascending systolic pressure post-intervention than OAR (TEVAR: 137±9mmHg vs OAR: 126±6mmHg, p=0.017). After the intervention, a significant discrepancy in the mean pressure differences between the ascending and descending aorta ΔP was observed (TEVAR: 9±3mmHg vs OAR: 1±2mmHg, p=0.004). Input impedance at zero frequency, approximating Windkessel resistance, was higher for TEVAR than for OAR (TEVAR: 1.78±0.04 vs OAR: 1.66±0.03mmHgs/ml, p=0.004). A correlation was found between the resistance and the negative peak of the time-normalized wave intensity analysis (Kendall's coefficient τ=-0.35 and p=0.023). Another correlation was observed between resistance and ΔP (τ=0.51, p=0.001). Looking at the replication of heart rate and stroke volume over the course of the study, the observed differences can largely be attributed to the type of intervention. The results suggest that TEVAR has adverse effects compared to OAR, particularly with regard to left ventricular afterload. Clinicians should consider the possibility of increased afterload and altered wave dynamics when deciding on TEVAR, particularly in patients with pre-existing impaired cardiovascular conditions.

Acta BiomaterialiaVol. 192
Medical University of Graz (AT), Norwegian University of Science and Technology (NO), Graz University of Technology (AT)
Zero hunger
Openalex Percentile: Top 14%
Aortic Disease and Treatment Approaches
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.