METAL DEBRIS RELEASE IN TOTAL KNEE ARTHROPLASTY: AN OVERLOOKED CLINICAL CONCERN
Objectives Several studies have reported elevated blood cobalt (Co) and chromium (Cr) concentrations in patients with total knee replacements (TKRs). Up to 44% of tissue samples taken from patients with failed TKRs exhibit histological evidence of metal sensitivity/ALVAL. In simulated conditions, metal particles contribute approximately 12% of total wear debris in TKR. We carried out this investigation to determine the source and quantity of metal release in TKRs. Design and Methods We analysed 225 explanted fixed-bearing TKRs (Attune, Genesis II, NexGen, PFC, and Vanguard) revised for any indication. These were analysed using peer-reviewed [coordinate measuring machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D profilometry (surface roughness-Ra) and light microscopy. Histological and blood metal ion concentration analyses were performed in a sub-sample of patients. Results The median (IQR) PE wear rate was 14 (6 to 20) mm 3 /year. Microscopic examination of the superior surface of trays exhibited pitting on 132 (59%) of trays. There was a statistically significant (p<0.05) increase in Rvk on the pitted area of trays for each design, indicating material removal from the pits compared to the unpitted area. The inferior surface of 116(51%) of trays displayed polishing, indicative of abrasive wear. The median(range) Co and Cr concentrations were 2.5µg/l (0.2–69.4) and 1.7µg/l (0.5-12.5) respectively in 40 patients. Of the tissue samples examined in 30 patients, 6 had at least “mild”-ALVAL infiltrate. All corresponding “ALVAL” explants were found to be pitted and/or show evidence of loosening of the tray. Conclusion This study provides further evidence that CoCr release in TKR appears to be an under-appreciated cause of adverse clinical outcomes. The generation of metal particles was predominantly from the metal tray, which may explain elevated metal ions after TKRs, despite no direct metal-on-metal contact.
Authors
- Stephen R. Wells (ORCID: https://orcid.org/0000-0002-8042-6460)
- David Langton (ORCID: https://orcid.org/0000-0003-1178-3031)
- Rohan Bhalekar (ORCID: https://orcid.org/0000-0002-5230-719X)
- Matthew Nargol
- Moreica Pabbruwe (ORCID: https://orcid.org/0000-0002-4223-0416)
- Sonali Natu (ORCID: https://orcid.org/0000-0002-5089-9726)
- Raghavendra Sidaginamale
- A. V. F. Nargol
- Susan Waller
Publication Details
- Journal
- Orthopaedic Proceedings
- Published
- 2024-12-12
- DOI
- https://doi.org/10.1302/1358-992x.2024.20.012
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00