Suppression of Current Harmonics in Grid-Connected inverter Using Equivalent Odd Proportional Multi-Resonant Controller

The current harmonics will seriously degrade the power quality of injected current in the gird connected inverter. The proportional resonant (PR) control as effective method can selectively suppress current harmonics at a certain frequency. However, proportional multi-resonant controllers(PMR) will greatly increase the structure complexity and calculation burden. In this paper, an equivalent odd proportional multi-resonant (OPMR) control based on repetitive control (RC) is proposed. Compared with PMR control, the proposed controller is simpler in structure, and multiple odd harmonics can be inhibited simultaneously. Whats more, a complete equivalent mathematical relationship between PMR and OPMR is presented. The validity of proposed method is proved by simulation and experimental results.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1109/dtpi61353.2024.10778760
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suppression of Current Harmonics in Grid-Connected inverter Using Equivalent Odd Proportional Multi-Resonant Controller

Jinghua Zhou, Yifei Sun, Shasha Chen, Bakhramov Shokhrukhbek
Microgrid Control and Optimization
article

Suppression of Current Harmonics in Grid-Connected inverter Using Equivalent Odd Proportional Multi-Resonant Controller

Jinghua Zhou, Yifei Sun, Shasha Chen, Bakhramov Shokhrukhbek
article en

Abstract

The current harmonics will seriously degrade the power quality of injected current in the gird connected inverter. The proportional resonant (PR) control as effective method can selectively suppress current harmonics at a certain frequency. However, proportional multi-resonant controllers(PMR) will greatly increase the structure complexity and calculation burden. In this paper, an equivalent odd proportional multi-resonant (OPMR) control based on repetitive control (RC) is proposed. Compared with PMR control, the proposed controller is simpler in structure, and multiple odd harmonics can be inhibited simultaneously. Whats more, a complete equivalent mathematical relationship between PMR and OPMR is presented. The validity of proposed method is proved by simulation and experimental results.

North China University of Technology (CN), Andijan State Medical Institute (UZ), Andijan Machine-building Institute (UZ)
North China University of Technology
Affordable and clean energy
Openalex Percentile: Top 73%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.