Microneedle Uric Acid Biosensor With Graphite Ink and Electrodeposited MWCNT

This article reports on the development of a wearable biosensor for high-sensitivity uric acid detection, utilizing graphite ink and multiwalled carbon nanotubes (GP/MWCNTs). This microneedle biosensor achieves high sensitivity (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1200~\mu $ </tex-math></inline-formula> Acm<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{2}}$ </tex-math></inline-formula> mM<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>) and a broad linear detection range (0–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1500~\mu $ </tex-math></inline-formula> M), thereby covering both healthy individuals and gout patients. An exceptionally low detection limit was achieved, with <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.053~\mu $ </tex-math></inline-formula> M measured by differential pulse voltammetry (DPV) and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$18.34~\mu $ </tex-math></inline-formula> M measured by continuous amperometry using a microfluidic system. This microneedle biosensor’s structure incorporates three medical-grade ultrafine stainless-steel needles designated as the reference electrode (RE), counter electrode (CE), and working electrode (WE), ensuring safe skin penetration and biocompatibility. Selectivity studies in a microfluidic system have shown that common interfering substances such as glucose do not affect the biosensor’s response, enhancing the specificity of uric acid detection. During the development process, MWCNTs were electrochemically deposited onto a layer of graphite ink formed on the ultrafine stainless-steel needles. This technique ensures a robust and stable microneedle-type biosensor that minimizes manufacturing processes and is unaffected by external disturbances such as friction. While carbon ink has been commonly used in uric acid detection sensors, this study found that graphite ink with MWCNTs on the electrodes significantly enhances the sensitivity for uric acid. This improvement is believed to be due to the smooth electron transfer through the multiple layered structures at the WE. This discovery and the high detection capability have the potential to enhance the performance of biosensors in medical fields where accurate monitoring of uric acid levels is crucial.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-12-12
DOI
https://doi.org/10.1109/jsen.2024.3512574
Citations
4
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microneedle Uric Acid Biosensor With Graphite Ink and Electrodeposited MWCNT

Hiroshi Kawahira, Jun Kameoka, Toru Nohgi, Yifan Tu
4 citations
IEEE Sensors Journal
Advanced Chemical Sensor Technologies
0.74
article

Microneedle Uric Acid Biosensor With Graphite Ink and Electrodeposited MWCNT

Hiroshi Kawahira, Jun Kameoka, Toru Nohgi, Yifan Tu
article en
4 citations

Abstract

This article reports on the development of a wearable biosensor for high-sensitivity uric acid detection, utilizing graphite ink and multiwalled carbon nanotubes (GP/MWCNTs). This microneedle biosensor achieves high sensitivity (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1200~\mu $ </tex-math></inline-formula> Acm<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{2}}$ </tex-math></inline-formula> mM<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$^{-{1}}$ </tex-math></inline-formula>) and a broad linear detection range (0–<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1500~\mu $ </tex-math></inline-formula> M), thereby covering both healthy individuals and gout patients. An exceptionally low detection limit was achieved, with <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.053~\mu $ </tex-math></inline-formula> M measured by differential pulse voltammetry (DPV) and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$18.34~\mu $ </tex-math></inline-formula> M measured by continuous amperometry using a microfluidic system. This microneedle biosensor’s structure incorporates three medical-grade ultrafine stainless-steel needles designated as the reference electrode (RE), counter electrode (CE), and working electrode (WE), ensuring safe skin penetration and biocompatibility. Selectivity studies in a microfluidic system have shown that common interfering substances such as glucose do not affect the biosensor’s response, enhancing the specificity of uric acid detection. During the development process, MWCNTs were electrochemically deposited onto a layer of graphite ink formed on the ultrafine stainless-steel needles. This technique ensures a robust and stable microneedle-type biosensor that minimizes manufacturing processes and is unaffected by external disturbances such as friction. While carbon ink has been commonly used in uric acid detection sensors, this study found that graphite ink with MWCNTs on the electrodes significantly enhances the sensitivity for uric acid. This improvement is believed to be due to the smooth electron transfer through the multiple layered structures at the WE. This discovery and the high detection capability have the potential to enhance the performance of biosensors in medical fields where accurate monitoring of uric acid levels is crucial.

IEEE Sensors JournalVol. 25(3)
Jichi Medical University (JP), Waseda University (JP)
Affordable and clean energy
Openalex Percentile: Top 31%
Advanced Chemical Sensor Technologies
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.