MRI Joint Superresolution and Denoising Based on Conditional Stochastic Normalizing Flow

Magnetic resonance imaging (MRI) is often limited by noise and low-resolution (LR), which can impact the precision of the diagnosis and treatment of patients. LR images and mixed noise (e.g., Gaussian noise, Rician noise, and Impulse noise) are inherent in MR images, and current approaches typically address image superresolution (SR) reconstruction and denoising separately, resulting in a discrepancy between the actual MRI data distribution and the reconstructed images. This research introduces a new algorithm SRDSNF, the stochastic normalizing flow-based MR image SR and denoising model, which tackles SR and denoising simultaneously through a stochastic normalizing flow. Our method integrates the encoded information of the input image as a conditional variable in each reverse step of the stochastic normalizing flow, ensuring a consistent representation of the spatial distribution between the reconstructed image and the original data. Additionally, we incorporate range-null space decomposition and subsequence sampling techniques to increase the consistency between the original and constructed data and accelerate model generation. To assess the efficacy of our approach, we conducted experiments on the BrainWeb and NFBS datasets, which include simultaneous SR and denoising, standalone denoising, and standalone SR tasks. The results of the experiments illustrate that our method achieves superior SR and denoising performance with fewer sampling steps, closely approximating the ground truths. Furthermore, our results surpass those of existing methods in various tasks, showing improvement of up to 4.64 dB in PSNR and 13.8% in SSIM achieved by our SRDSNF model was contextualized against state-of-the-art approaches such as AMIR, SwinIR, and InstructIR. These methods typically report PSNR improvements ranging from 0.5 to 2 dB and SSIM increases of 3%–6%, underscoring the potential clinical value of our methodology.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Artificial Intelligence
Published
2024-12-12
DOI
https://doi.org/10.1109/tai.2024.3515936
Citations
2
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
0.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI Joint Superresolution and Denoising Based on Conditional Stochastic Normalizing Flow

Xingce Wang, Zhenhong Liu, Zhongke Wu
2 citations
IEEE Transactions on Artificial Intelligence
Image and Signal Denoising Methods
0.50
article

MRI Joint Superresolution and Denoising Based on Conditional Stochastic Normalizing Flow

Xingce Wang, Zhenhong Liu, Zhongke Wu
article en
2 citations

Abstract

Magnetic resonance imaging (MRI) is often limited by noise and low-resolution (LR), which can impact the precision of the diagnosis and treatment of patients. LR images and mixed noise (e.g., Gaussian noise, Rician noise, and Impulse noise) are inherent in MR images, and current approaches typically address image superresolution (SR) reconstruction and denoising separately, resulting in a discrepancy between the actual MRI data distribution and the reconstructed images. This research introduces a new algorithm SRDSNF, the stochastic normalizing flow-based MR image SR and denoising model, which tackles SR and denoising simultaneously through a stochastic normalizing flow. Our method integrates the encoded information of the input image as a conditional variable in each reverse step of the stochastic normalizing flow, ensuring a consistent representation of the spatial distribution between the reconstructed image and the original data. Additionally, we incorporate range-null space decomposition and subsequence sampling techniques to increase the consistency between the original and constructed data and accelerate model generation. To assess the efficacy of our approach, we conducted experiments on the BrainWeb and NFBS datasets, which include simultaneous SR and denoising, standalone denoising, and standalone SR tasks. The results of the experiments illustrate that our method achieves superior SR and denoising performance with fewer sampling steps, closely approximating the ground truths. Furthermore, our results surpass those of existing methods in various tasks, showing improvement of up to 4.64 dB in PSNR and 13.8% in SSIM achieved by our SRDSNF model was contextualized against state-of-the-art approaches such as AMIR, SwinIR, and InstructIR. These methods typically report PSNR improvements ranging from 0.5 to 2 dB and SSIM increases of 3%–6%, underscoring the potential clinical value of our methodology.

IEEE Transactions on Artificial IntelligenceVol. 6(6)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking University (CN), Beijing Normal University (CN), Peking Union Medical College Hospital (CN), University of Manchester (GB), Peking University Third Hospital (CN)
Openalex Percentile: Top 33%
Image and Signal Denoising Methods
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.