One-Step Electrochemical Modification of PEDOT:PSS/PBNPs Hybrid Hydrogel on the Screen-Printed Electrode Surface for Highly Sensitive Detection of Creatinine

Creatinine (CRE) is frequently measured in clinical practice due to its recognized significance as a pivotal biomarker across a spectrum of renal and cardiovascular disorders. However, the rapid and accurate detection of CRE for assessing kidney and muscle functions remains challenging. Here, we prepared the poly(3,4ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) hydrogel uniformly loaded with Prussian blue nanoparticles (PBNPs) via a one-step metal-assisted electrochemical modification method on the screen-printed electrode for ultrasensitive CRE detection. The conductive, porous PEDOT:PSS/PBNPs hydrogel provided a confined space that facilitated highly efficient biocatalytic cascade reactions of creatinine amidohydrolase, creatine amidinohydrolase (Cl), and sarcosine oxidase, enabling the CRE detection with a high sensitivity (40.2 μA mM<sup>-1</sup> cm<sup>-2</sup>), a wide linear detection range (20-600 μM), and a low detection limit (8.3 μM). What is more, we developed an integrated platform utilizing a differential strategy to eliminate the interference from endogenous creatine (CR), employing a dual-channel working electrode for independent CR and CRE detection, along with modules for signal processing and wireless communication. The differential method and system were validated in simulated blood, the detection error was reduced from 41.1% to 8.89% after applying the differential method, and the recoveries ranged from 89.5% to 107.8%, with errors remaining below 12%. This PEDOT:PSS/PBNPs hydrogel CRE biosensor, based on one-step modification method, offered a promising strategy for precise assessment of kidney and muscle health in both clinical and at-home settings.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-12-11
DOI
https://doi.org/10.1021/acsami.4c17451
Citations
7
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Step Electrochemical Modification of PEDOT:PSS/PBNPs Hybrid Hydrogel on the Screen-Printed Electrode Surface for Highly Sensitive Detection of Creatinine

Tong Liu, Bo Liang, Yu Cai, Jun Zhang et al.
7 citations
ACS Applied Materials & Interfaces
Electrochemical sensors and biosensors
1.46
article

One-Step Electrochemical Modification of PEDOT:PSS/PBNPs Hybrid Hydrogel on the Screen-Printed Electrode Surface for Highly Sensitive Detection of Creatinine

Tong Liu, Bo Liang, Yu Cai, Jun Zhang, Shanshan Zhang, Wanying Chen, Fang Lü, Yelan Yao, Yukun Ma, Yue Zhou, Dong Wang
article en
7 citations

Abstract

Creatinine (CRE) is frequently measured in clinical practice due to its recognized significance as a pivotal biomarker across a spectrum of renal and cardiovascular disorders. However, the rapid and accurate detection of CRE for assessing kidney and muscle functions remains challenging. Here, we prepared the poly(3,4ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) hydrogel uniformly loaded with Prussian blue nanoparticles (PBNPs) via a one-step metal-assisted electrochemical modification method on the screen-printed electrode for ultrasensitive CRE detection. The conductive, porous PEDOT:PSS/PBNPs hydrogel provided a confined space that facilitated highly efficient biocatalytic cascade reactions of creatinine amidohydrolase, creatine amidinohydrolase (Cl), and sarcosine oxidase, enabling the CRE detection with a high sensitivity (40.2 μA mM<sup>-1</sup> cm<sup>-2</sup>), a wide linear detection range (20-600 μM), and a low detection limit (8.3 μM). What is more, we developed an integrated platform utilizing a differential strategy to eliminate the interference from endogenous creatine (CR), employing a dual-channel working electrode for independent CR and CRE detection, along with modules for signal processing and wireless communication. The differential method and system were validated in simulated blood, the detection error was reduced from 41.1% to 8.89% after applying the differential method, and the recoveries ranged from 89.5% to 107.8%, with errors remaining below 12%. This PEDOT:PSS/PBNPs hydrogel CRE biosensor, based on one-step modification method, offered a promising strategy for precise assessment of kidney and muscle health in both clinical and at-home settings.

ACS Applied Materials & InterfacesVol. 16(51)
Sir Run Run Shaw Hospital (CN), Ministry of Education (TH), Institute of Automation (DE), Hangzhou Dianzi University (CN), Zhejiang University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 17%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.