Preparation of epoxy resin cavity defect sample and research on partial discharge characteristic of three different cavity size

Epoxy resin as an excellent material is widely used in various power equipment. Therefore, for the safe and stable operation of power equipment, it is necessary to study the internal defects of epoxy resin. Although many studies have clarified the preparation method of defect samples and the fundamental phenomenon of deterioration caused by partial discharge (PD) occurring due to defects in inner epoxy, little is known about whether the defect model conforms to the reality. The relation between cavity size and discharge is not clear as well. Hence, this paper provides a realistic and convenient way to generate cavity defect samples by using a pipette gun. Partial discharge measurements with three different sensors have been used to understand the role of cavity size in the process of discharge in the cavity sample. Fast Fourier Transform is also used to study the relation between the frequency of discharge signal and cavity size. The result suggests that the size of cavity does have an effect on the discharge amplitude and the discharge frequency.

Authors

Institutions

Publication Details

Published
2024-12-11
DOI
https://doi.org/10.1117/12.3052702
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of epoxy resin cavity defect sample and research on partial discharge characteristic of three different cavity size

Huang Junkai, Lin Chen, Bo Li, Song Deng et al.
High voltage insulation and dielectric phenomena
article

Preparation of epoxy resin cavity defect sample and research on partial discharge characteristic of three different cavity size

Huang Junkai, Lin Chen, Bo Li, Song Deng, Yi Xing
article en

Abstract

Epoxy resin as an excellent material is widely used in various power equipment. Therefore, for the safe and stable operation of power equipment, it is necessary to study the internal defects of epoxy resin. Although many studies have clarified the preparation method of defect samples and the fundamental phenomenon of deterioration caused by partial discharge (PD) occurring due to defects in inner epoxy, little is known about whether the defect model conforms to the reality. The relation between cavity size and discharge is not clear as well. Hence, this paper provides a realistic and convenient way to generate cavity defect samples by using a pipette gun. Partial discharge measurements with three different sensors have been used to understand the role of cavity size in the process of discharge in the cavity sample. Fast Fourier Transform is also used to study the relation between the frequency of discharge signal and cavity size. The result suggests that the size of cavity does have an effect on the discharge amplitude and the discharge frequency.

Guizhou Electric Power Design and Research Institute (CN)
Clean water and sanitation
Openalex Percentile: Top 86%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.