A concept for sensor system developments using raw-milk monitoring as a case study

Abstract. In this work, we present a concept for a raw-milk monitoring sensor system aiming at demonstrating a generalized approach for low-cost gas sensor system development in future. These systems are expected to be comparatively less expensive than conventional gas chromatography (GC) systems and can therefore likewise be used by farmers to monitor on-site storage as well as by dairy companies for the inspection of incoming milk and can thus play a significant role in counteracting the waste of milk and its products. This generalizable method is based on three steps: identification of potential milk degradation markers, quantification of these markers, and characterization of metal oxide semiconductor (MOS) sensors for these markers. In the first step, gas chromatography–mass spectrometry (GC-MS) and GC–flame ionization detector (GC-FID)/olfactometry (O) were used to tentatively identify 14 volatile substances in the headspace concentrations above the raw milk. From this, 3-methylbutan-1-ol, hexan-1-ol, pentan-1-ol, acetic acid, and additionally ethanol and ethyl acetate were selected by cross-referencing our results with literature data. In addition, hexanal, 2-methyl-1-propanol, limonene, nonanal, 2-ethylhexan-1-ol, butanoic acid, hexanoic acid, octanoic acid, methyl hexadecanoate, and decanoic acid were identified but not selected as potential markers due to their properties being incompatible with gas mixing apparatus (GMA). In the second step, a proton transfer reaction–MS (PTR-MS) analysis was used to determine the concentration in the headspace, which is in the parts per billion (ppb) range. Investigations of good milk samples and bad milk samples from alpine farms showed that ethanol, 3-methylbutan-1-ol, pentan-1-ol, and hexan-1-ol offered an increasing trend from good to bad milk samples. To enable more precise differentiation, further investigations with a higher sample size are necessary to reveal the feasibility of these markers within the complex matrix of raw milk. In the third step, these selected and literature-confirmed markers were presented to a commercially available sensor, run in a temperature-cycled operation and characterized by a self-developed system. When using ethanol, pentan-1-ol, and hexan-1-ol, a regression model with an accuracy of 42.9 ppb using partial least-squares regression (PLSR) analysis could be established, enabling such sensors to be used in raw-milk monitoring systems in the future.

Authors

Institutions

Publication Details

Journal
Journal of sensors and sensor systems
Published
2024-12-11
DOI
https://doi.org/10.5194/jsss-13-263-2024
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A concept for sensor system developments using raw-milk monitoring as a case study

A. Stenzel, Maximilian Koehne, Sabine Trupp, Tilman Sauerwald et al.
1 citations
Journal of sensors and sensor systems
Advanced Chemical Sensor Technologies
0.18
article

A concept for sensor system developments using raw-milk monitoring as a case study

A. Stenzel, Maximilian Koehne, Sabine Trupp, Tilman Sauerwald, Michael Henfling, Kristina Amtmann, Gina Zeh, Andrea Buettner
article en
1 citations

Abstract

Abstract. In this work, we present a concept for a raw-milk monitoring sensor system aiming at demonstrating a generalized approach for low-cost gas sensor system development in future. These systems are expected to be comparatively less expensive than conventional gas chromatography (GC) systems and can therefore likewise be used by farmers to monitor on-site storage as well as by dairy companies for the inspection of incoming milk and can thus play a significant role in counteracting the waste of milk and its products. This generalizable method is based on three steps: identification of potential milk degradation markers, quantification of these markers, and characterization of metal oxide semiconductor (MOS) sensors for these markers. In the first step, gas chromatography–mass spectrometry (GC-MS) and GC–flame ionization detector (GC-FID)/olfactometry (O) were used to tentatively identify 14 volatile substances in the headspace concentrations above the raw milk. From this, 3-methylbutan-1-ol, hexan-1-ol, pentan-1-ol, acetic acid, and additionally ethanol and ethyl acetate were selected by cross-referencing our results with literature data. In addition, hexanal, 2-methyl-1-propanol, limonene, nonanal, 2-ethylhexan-1-ol, butanoic acid, hexanoic acid, octanoic acid, methyl hexadecanoate, and decanoic acid were identified but not selected as potential markers due to their properties being incompatible with gas mixing apparatus (GMA). In the second step, a proton transfer reaction–MS (PTR-MS) analysis was used to determine the concentration in the headspace, which is in the parts per billion (ppb) range. Investigations of good milk samples and bad milk samples from alpine farms showed that ethanol, 3-methylbutan-1-ol, pentan-1-ol, and hexan-1-ol offered an increasing trend from good to bad milk samples. To enable more precise differentiation, further investigations with a higher sample size are necessary to reveal the feasibility of these markers within the complex matrix of raw milk. In the third step, these selected and literature-confirmed markers were presented to a commercially available sensor, run in a temperature-cycled operation and characterized by a self-developed system. When using ethanol, pentan-1-ol, and hexan-1-ol, a regression model with an accuracy of 42.9 ppb using partial least-squares regression (PLSR) analysis could be established, enabling such sensors to be used in raw-milk monitoring systems in the future.

Journal of sensors and sensor systemsVol. 13(2)
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Universität der Bundeswehr München (DE), Forschungszentrum Küste (DE), Fraunhofer Institute for Process Engineering and Packaging (DE), Fraunhofer Research Institution for Microsystems and Solid State Technologies (DE), Saarland University (DE)
Bayerische Forschungsstiftung, Universität des Saarlandes, Bayerische Staatsministerium für Wirtschaft, Landesentwicklung und Energie
Openalex Percentile: Top 50%
Advanced Chemical Sensor Technologies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.