Detection and perception of inspiratory resistive loads in older adults with and without chronic obstructive pulmonary disease

Impairments in the detection and perception of resistive loads in healthy aging and chronic obstructive pulmonary disease (COPD) have implications for airway protection and breathlessness. This study investigated load detection and perception in 18 participants with COPD, 17 older adults [i.e., age-matched controls (AMCs)] and 23 young adults [i.e., young controls (YCs)]. Load detection was assessed as the minimal change in airway resistance that could be detected and load perception as the perceived level of effort to breathe through a series of suprathreshold resistive loads, rated on a modified Borg scale. Young and older adults, with and without COPD, could detect similar changes in resistance (∼0.7 cmH<sub>2</sub>O/L/s) and inspiratory pressure (∼0.5 cmH<sub>2</sub>O), although this equated to a smaller proportion of predicted maximal inspiratory pressure (MIPpred) for young adults (∼0.5% MIPpred) compared with older adults with and without COPD (∼1.0% MIPpred; <i>P</i> < 0.001). For load perception, the relationship between Borg ratings and resistance was steeper in older adult controls compared with both young adults (<i>P</i> < 0.001) and older adults with COPD (<i>P</i> < 0.01). Borg rating slopes were comparable across all participant groups with changes in inspiratory pressure. There was no correlation between load detection threshold and load perception. In older adults, heightened perception of loaded breaths with large changes in breathing resistance may be due to an increased effort to breathe at these loads.<b>NEW & NOTEWORTHY</b> We demonstrated that young adults could detect a smaller change in pressure (as a proportion of predicted maximal inspiratory pressure) than older adults. The perceived effort to breathe with increases in the resistance of breathing was heightened in older, compared with young adults. There was no further impairment in chronic obstructive pulmonary disease. Heightened dyspnea perception related to the effort to breathe was not associated with load detection thresholds in older adults.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physiology
Published
2024-12-11
DOI
https://doi.org/10.1152/japplphysiol.00398.2024
Citations
1
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection and perception of inspiratory resistive loads in older adults with and without chronic obstructive pulmonary disease

Claire L. Boswell‐Ruys, Isabella Epiu, Jane E. Butler, Anna L. Hudson et al.
1 citations
Journal of Applied Physiology
Noise Effects and Management
0.87
article

Detection and perception of inspiratory resistive loads in older adults with and without chronic obstructive pulmonary disease

Claire L. Boswell‐Ruys, Isabella Epiu, Jane E. Butler, Anna L. Hudson, Simon C. Gandevia, David A. Nguyen
article en
1 citations

Abstract

Impairments in the detection and perception of resistive loads in healthy aging and chronic obstructive pulmonary disease (COPD) have implications for airway protection and breathlessness. This study investigated load detection and perception in 18 participants with COPD, 17 older adults [i.e., age-matched controls (AMCs)] and 23 young adults [i.e., young controls (YCs)]. Load detection was assessed as the minimal change in airway resistance that could be detected and load perception as the perceived level of effort to breathe through a series of suprathreshold resistive loads, rated on a modified Borg scale. Young and older adults, with and without COPD, could detect similar changes in resistance (∼0.7 cmH<sub>2</sub>O/L/s) and inspiratory pressure (∼0.5 cmH<sub>2</sub>O), although this equated to a smaller proportion of predicted maximal inspiratory pressure (MIPpred) for young adults (∼0.5% MIPpred) compared with older adults with and without COPD (∼1.0% MIPpred; <i>P</i> < 0.001). For load perception, the relationship between Borg ratings and resistance was steeper in older adult controls compared with both young adults (<i>P</i> < 0.001) and older adults with COPD (<i>P</i> < 0.01). Borg rating slopes were comparable across all participant groups with changes in inspiratory pressure. There was no correlation between load detection threshold and load perception. In older adults, heightened perception of loaded breaths with large changes in breathing resistance may be due to an increased effort to breathe at these loads.<b>NEW & NOTEWORTHY</b> We demonstrated that young adults could detect a smaller change in pressure (as a proportion of predicted maximal inspiratory pressure) than older adults. The perceived effort to breathe with increases in the resistance of breathing was heightened in older, compared with young adults. There was no further impairment in chronic obstructive pulmonary disease. Heightened dyspnea perception related to the effort to breathe was not associated with load detection thresholds in older adults.

Journal of Applied PhysiologyVol. 138(1)
Flinders University (AU), Kabale University (UG), UNSW Sydney (AU), Neuroscience Research Australia (AU)
Rebecca L. Cooper Medical Research Foundation, University of New South Wales, Lung Foundation Australia, National Health and Medical Research Council
Good health and well-being
Openalex Percentile: Top 19%
Noise Effects and Management
0.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.