Design and motion analysis of a coaxial ankle rehabilitation device

Abstract Ankle joint is an important joint related to walking in the human body. It is also a joint that is easy to leave sequelae in all joints of stroke patients. According to the physiological characteristics of the human ankle and the characteristics of ankle rehabilitation institutions, the overall structure of the coaxial ankle rehabilitation robot is designed, and the motion principle of the coaxial transmission mechanism is emphatically introduced. Using SolidWorks software to simulate the kinematics of the virtual prototype, and comparing the simulation data with the theoretical data, the accuracy of theoretical analysis and the feasibility of mechanism design are verified, which provides a theoretical basis for the subsequent mechanism size optimization design.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-12-01
DOI
https://doi.org/10.1088/1742-6596/2926/1/012013
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and motion analysis of a coaxial ankle rehabilitation device

Sifan Wu, Jinqiang Ye, Shuai Chen, Hui‐Yi Zeng et al.
Journal of Physics Conference Series
Stroke Rehabilitation and Recovery
article

Design and motion analysis of a coaxial ankle rehabilitation device

Sifan Wu, Jinqiang Ye, Shuai Chen, Hui‐Yi Zeng, Yage Wang, Chen-Fu Huang
article en

Abstract

Abstract Ankle joint is an important joint related to walking in the human body. It is also a joint that is easy to leave sequelae in all joints of stroke patients. According to the physiological characteristics of the human ankle and the characteristics of ankle rehabilitation institutions, the overall structure of the coaxial ankle rehabilitation robot is designed, and the motion principle of the coaxial transmission mechanism is emphatically introduced. Using SolidWorks software to simulate the kinematics of the virtual prototype, and comparing the simulation data with the theoretical data, the accuracy of theoretical analysis and the feasibility of mechanism design are verified, which provides a theoretical basis for the subsequent mechanism size optimization design.

Journal of Physics Conference SeriesVol. 2926(1)
Dongguan University of Technology (CN)
Good health and well-being
Openalex Percentile: Top 72%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.