Simultaneous Temperature and Relative Humidity Measurement Using Machine Learning in Rayleigh-Based Optical Frequency Domain Reflectometry

This paper presents, for the first time to the best of our knowledge, simultaneous temperature and relative humidity (RH) measurement using a machine learning (ML) model in Rayleigh-based Optical Frequency Domain Reflectometry (OFDR). The sensor unit consists of two segments: bare and polyimide-coated fibers, each with different sensitivities to temperature. The polyimide-coated fiber is RH-sensitive, unlike the bare fiber. We propose the ML approach to avoid manual post-processing data and maintain relatively high accuracy of the sensor. The root mean square error (RMSE) values for the 3 cm length of the sensor unit were 0.36 °C and 1.73% RH for temperature and RH, respectively. Furthermore, we investigated the impact of sensor unit lengths and number of data points on RMSE values. This approach eliminates the need for manual data processing, reduces analysis time, and enables accurate, simultaneous measurement of temperature and RH in Rayleigh-based OFDR.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-11
DOI
https://doi.org/10.3390/s24247913
Citations
5
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Temperature and Relative Humidity Measurement Using Machine Learning in Rayleigh-Based Optical Frequency Domain Reflectometry

Bogusław Szczupak, Mateusz Mądry, Mateusz Śmigielski, Bartosz Matysiak
5 citations
Sensors
Advanced Fiber Optic Sensors
1.04
article

Simultaneous Temperature and Relative Humidity Measurement Using Machine Learning in Rayleigh-Based Optical Frequency Domain Reflectometry

Bogusław Szczupak, Mateusz Mądry, Mateusz Śmigielski, Bartosz Matysiak
article en
5 citations

Abstract

This paper presents, for the first time to the best of our knowledge, simultaneous temperature and relative humidity (RH) measurement using a machine learning (ML) model in Rayleigh-based Optical Frequency Domain Reflectometry (OFDR). The sensor unit consists of two segments: bare and polyimide-coated fibers, each with different sensitivities to temperature. The polyimide-coated fiber is RH-sensitive, unlike the bare fiber. We propose the ML approach to avoid manual post-processing data and maintain relatively high accuracy of the sensor. The root mean square error (RMSE) values for the 3 cm length of the sensor unit were 0.36 °C and 1.73% RH for temperature and RH, respectively. Furthermore, we investigated the impact of sensor unit lengths and number of data points on RMSE values. This approach eliminates the need for manual data processing, reduces analysis time, and enables accurate, simultaneous measurement of temperature and RH in Rayleigh-based OFDR.

SensorsVol. 24(24)
Wrocław University of Science and Technology (PL), AGH University of Krakow (PL)
Openalex Percentile: Top 22%
Advanced Fiber Optic Sensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.