To address the issues of complexity in operation, limited application scenarios, and inaccurate recognition in existing EMG testing systems, this paper presents the design and research of a wearable and portable EMG monitoring system suitable. The study uses Ag/AgCl patch electrodes to collect surface EMG (sEMG) signals at a frequency of 500 Hz. After preprocessing through linear interpolation, band-pass filtering, and notch filtering, features such as MAV, RMS, and iEMG are extracted. The LDA algorithm is used for gesture classification, and a user-friendly interface was developed using PyQt in PyCharm to enhance operational convenience and interaction efficiency. Experimental results show that the EMG signals collected by the system are of high quality, the algorithm performs well in recognizing different gestures, and it has excellent noise reduction capabilities. The system can continuously operate for about 8 hours, offering advantages of low cost, small size, easy operation, and stable performance, providing a theoretical foundation for portable personal EMG monitoring.

Authors

Institutions

Publication Details

Published
2024-10-18
DOI
https://doi.org/10.1145/3703847.3703880
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Research of a Wearable Portable Electromyography Monitoring System

Haonan Jin, Xinran Cheng, Xinyao Tang, Xinyi Zhang et al.
2 citations
Muscle activation and electromyography studies
0.37
article

Design and Research of a Wearable Portable Electromyography Monitoring System

Haonan Jin, Xinran Cheng, Xinyao Tang, Xinyi Zhang, Xupeng Wang, Hongyan Liu
article en
2 citations

Abstract

To address the issues of complexity in operation, limited application scenarios, and inaccurate recognition in existing EMG testing systems, this paper presents the design and research of a wearable and portable EMG monitoring system suitable. The study uses Ag/AgCl patch electrodes to collect surface EMG (sEMG) signals at a frequency of 500 Hz. After preprocessing through linear interpolation, band-pass filtering, and notch filtering, features such as MAV, RMS, and iEMG are extracted. The LDA algorithm is used for gesture classification, and a user-friendly interface was developed using PyQt in PyCharm to enhance operational convenience and interaction efficiency. Experimental results show that the EMG signals collected by the system are of high quality, the algorithm performs well in recognizing different gestures, and it has excellent noise reduction capabilities. The system can continuously operate for about 8 hours, offering advantages of low cost, small size, easy operation, and stable performance, providing a theoretical foundation for portable personal EMG monitoring.

Xi'an University of Technology (CN)
Openalex Percentile: Top 42%
Muscle activation and electromyography studies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.