Numerical Analysis of Wavefront Approximation Accuracy by Means of Zernike Polynomials for Optical Surface Flatness Measurements Using a Hartmannometer Device

A metrological device—Hartmannometer—based on a Shack-Hartmann wavefront sensor for measuring the flatness of optical surfaces was developed and researched, and the results were compared with the results obtained from measurements using a Fizeau interferometer. The paper presents a method for calibrating a Hartmannometer, and also compares the results of measuring a test optical surface using the developed device and a classical Fizeau interferometer. The total amplitude of wavefront distortions measured using a Fizeau interferometer was 0.127 μm (standard deviation 0.022 μm). The Hartmannometer showed distortions amplitude of 0.131 µm (standard deviation 0.024 µm).

Authors

Institutions

Publication Details

Journal
Optical Memory and Neural Networks
Published
2024-12-01
DOI
https://doi.org/10.3103/s1060992x24700395
Citations
2
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Analysis of Wavefront Approximation Accuracy by Means of Zernike Polynomials for Optical Surface Flatness Measurements Using a Hartmannometer Device

Alexis Kudryashov, Alexander Nikitin, Julia Sheldakova, Vladimir Toporovsky et al.
2 citations
Optical Memory and Neural Networks
Optical measurement and interference techniques
0.50
article

Numerical Analysis of Wavefront Approximation Accuracy by Means of Zernike Polynomials for Optical Surface Flatness Measurements Using a Hartmannometer Device

Alexis Kudryashov, Alexander Nikitin, Julia Sheldakova, Vladimir Toporovsky, Ilya Galaktionov
article en
2 citations

Abstract

A metrological device—Hartmannometer—based on a Shack-Hartmann wavefront sensor for measuring the flatness of optical surfaces was developed and researched, and the results were compared with the results obtained from measurements using a Fizeau interferometer. The paper presents a method for calibrating a Hartmannometer, and also compares the results of measuring a test optical surface using the developed device and a classical Fizeau interferometer. The total amplitude of wavefront distortions measured using a Fizeau interferometer was 0.127 μm (standard deviation 0.022 μm). The Hartmannometer showed distortions amplitude of 0.131 µm (standard deviation 0.024 µm).

Optical Memory and Neural NetworksVol. 33(S1)
Moscow Technical University of Communication and Informatics (RU), Institute of Geosphere Dynamics (RU)
Openalex Percentile: Top 33%
Optical measurement and interference techniques
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.