Protocol Reverse Analysis of Ethernet for Control Automation Technology Based on Sequence Alignment and Pearson Correlation Coefficient

This study presents a novel algorithm for protocol reverse analysis of EtherCAT. The algorithm combines sequence alignment and the Pearson correlation coefficient. We utilize value distribution statistics and the bit flip rate algorithm to effectively partition the protocol fields. We propose a semantics analysis method based on sequence alignment when HMI data and EtherCAT messages have a direct correlation. Conversely, for circumstances where there exists a decoding relationship between HMI data and EtherCAT messages, a semantic analysis method is proposed that employs the Pearson correlation coefficient. We completed a reverse analysis of the EtherCAT messages from an industrial robot system. By comparing the experiment results with the protocol description document, we validated the effectiveness of the method.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-11
DOI
https://doi.org/10.3390/s24247922
Citations
5
Primary Topic
Network Time Synchronization Technologies
Type
article
Field-Weighted Citation Impact
1.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protocol Reverse Analysis of Ethernet for Control Automation Technology Based on Sequence Alignment and Pearson Correlation Coefficient

Yunsong Tian, Zhongwei Li, Xiaopeng Wang, Yu Yao et al.
5 citations
Sensors
Network Time Synchronization Technologies
1.74
article

Protocol Reverse Analysis of Ethernet for Control Automation Technology Based on Sequence Alignment and Pearson Correlation Coefficient

Yunsong Tian, Zhongwei Li, Xiaopeng Wang, Yu Yao, Changhe Su
article en
5 citations

Abstract

This study presents a novel algorithm for protocol reverse analysis of EtherCAT. The algorithm combines sequence alignment and the Pearson correlation coefficient. We utilize value distribution statistics and the bit flip rate algorithm to effectively partition the protocol fields. We propose a semantics analysis method based on sequence alignment when HMI data and EtherCAT messages have a direct correlation. Conversely, for circumstances where there exists a decoding relationship between HMI data and EtherCAT messages, a semantic analysis method is proposed that employs the Pearson correlation coefficient. We completed a reverse analysis of the EtherCAT messages from an industrial robot system. By comparing the experiment results with the protocol description document, we validated the effectiveness of the method.

SensorsVol. 24(24)
NSK (United States) (US), Harbin Institute of Technology (CN), Northeastern University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 14%
Network Time Synchronization Technologies
1.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.