Preliminary mechanistic insights into the detection of ethanol vapour using MnO2 NRs-CNPs-poly-4-(vinylpyridine) based solid-state sensor operating at room temperature

Semiconductor metal oxide gas sensors are widely used to detect ethanol vapours, commonly used in industrial productions, road safety detection, and solvent production; however, they operate at extremely high temperatures. In this work, we present manganese dioxide nanorods (MnO<sub>2</sub> NRs) prepared via hydrothermal synthetic route, carbon soot (CNPs) prepared via pyrolysis of lighthouse candle, and poly-4-vinylpyridine (P4VP) composite for the detection of ethanol vapour at room temperature. MnO<sub>2</sub>, CNPs, P4VP, and MnO<sub>2</sub> NRs-CNPs-P4VP composite were characterised using scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. Five sensors were prepared, namely, sensor 1 (MnO<sub>2</sub> <sub>-NRs)</sub>, sensor 2 (CNPs), sensor 3 (CNPs-P4VP composite of a mass ratio of 1:3), sensor 4 (MnO<sub>2</sub> NRs-CNPs-P4VP composite of a mass ratio 1:1:3), and sensor 5 (MnO<sub>2</sub> NRs-CNPs-P4VP composite of a mass ratio 2:1:3). All the five sensors were used detect to 2-propanol, acetone, ethanol, methanol, and mesitylene vapours at room temperature, but among all the tested sensors, sensor 4 was highly sensitive to ethanol vapour and less sensitive to 2-propanol, methanol, acetone, and mesitylene vapours. The response and recovery time of sensor 4 towards ethanol vapour at 20.4 ppm were 82 seconds and 74 seconds, respectively. The limit of detection on ethanol vapour using sensor 4 was 789 ppb. During detection, the ethanol vapour undergoes total deep oxidation on the surface of sensor 4.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-12-11
DOI
https://doi.org/10.1016/j.heliyon.2024.e40993
Citations
1
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary mechanistic insights into the detection of ethanol vapour using MnO2 NRs-CNPs-poly-4-(vinylpyridine) based solid-state sensor operating at room temperature

Lesego Malepe, Patrick Ndungu, Derek Tantoh Ndinteh, Messai A. Mamo
1 citations
Heliyon
Gas Sensing Nanomaterials and Sensors
0.21
article

Preliminary mechanistic insights into the detection of ethanol vapour using MnO2 NRs-CNPs-poly-4-(vinylpyridine) based solid-state sensor operating at room temperature

Lesego Malepe, Patrick Ndungu, Derek Tantoh Ndinteh, Messai A. Mamo
article en
1 citations

Abstract

Semiconductor metal oxide gas sensors are widely used to detect ethanol vapours, commonly used in industrial productions, road safety detection, and solvent production; however, they operate at extremely high temperatures. In this work, we present manganese dioxide nanorods (MnO<sub>2</sub> NRs) prepared via hydrothermal synthetic route, carbon soot (CNPs) prepared via pyrolysis of lighthouse candle, and poly-4-vinylpyridine (P4VP) composite for the detection of ethanol vapour at room temperature. MnO<sub>2</sub>, CNPs, P4VP, and MnO<sub>2</sub> NRs-CNPs-P4VP composite were characterised using scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. Five sensors were prepared, namely, sensor 1 (MnO<sub>2</sub> <sub>-NRs)</sub>, sensor 2 (CNPs), sensor 3 (CNPs-P4VP composite of a mass ratio of 1:3), sensor 4 (MnO<sub>2</sub> NRs-CNPs-P4VP composite of a mass ratio 1:1:3), and sensor 5 (MnO<sub>2</sub> NRs-CNPs-P4VP composite of a mass ratio 2:1:3). All the five sensors were used detect to 2-propanol, acetone, ethanol, methanol, and mesitylene vapours at room temperature, but among all the tested sensors, sensor 4 was highly sensitive to ethanol vapour and less sensitive to 2-propanol, methanol, acetone, and mesitylene vapours. The response and recovery time of sensor 4 towards ethanol vapour at 20.4 ppm were 82 seconds and 74 seconds, respectively. The limit of detection on ethanol vapour using sensor 4 was 789 ppb. During detection, the ethanol vapour undergoes total deep oxidation on the surface of sensor 4.

HeliyonVol. 11(1)
University of Johannesburg (ZA), University of Pretoria (ZA)
University of Johannesburg
Affordable and clean energy
Openalex Percentile: Top 45%
Gas Sensing Nanomaterials and Sensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.