Factors Associated With “Sterile Cystic Formation” Following the Application of BioGlue® in Brain Surgery and Review of Literature

Introduction BioGlue® (CryoLife, Inc, Kennesaw, GA), despite being claimed to be a safe and harmless sealant, reportedly has several adverse effects including surgical wound dehiscence. This study aimed to examine the factors that may contribute to this unfavorable outcome in cranial surgery. Methods A retrospective cross-sectional analysis was conducted on patients who underwent brain surgery with the use of BioGlue® between January 2015 and December 2022. One hundred and two individuals were enrolled and classified into two categories based on the incidence of surgical wound complications. The patients' demography, operative details, and the nature of their surgical wound problems were evaluated. Results Out of 102 individuals, 15 experienced postoperative wound complications. Fluid resembling pus was noted; however, laboratory cultures yielded negative results. Complications were significantly more prevalent (seven times higher) among individuals utilizing BioGlue® in proximity to titanium plates for skull defect correction. Patients using the 5 mL pre-filled BioGlue® device had a 2.8 times higher likelihood of complications than the 2 mL version. Using the patient's cranial bone as a barrier during surgery reduced the risk of complications. Conclusions Neurosurgeons should note possible adverse reactions of using a sealant for cranial surgery that include inflammation and wound separation. Treatment should include thorough cleansing and complete removal of BioGlue®. Two prevalent risk factors were the close proximity (direct contact) of BioGlue® to the adjacent titanium plate used for covering skull defect and the volume of sealant used (5 mL or 2 mL).

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-12-11
DOI
https://doi.org/10.7759/cureus.75523
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Associated With “Sterile Cystic Formation” Following the Application of BioGlue® in Brain Surgery and Review of Literature

Tatre Jantarakolica, Methee Wongsirisuwan, Nichapa Lerthirunvibul
Cureus
Surgical Sutures and Adhesives
article

Factors Associated With “Sterile Cystic Formation” Following the Application of BioGlue® in Brain Surgery and Review of Literature

Tatre Jantarakolica, Methee Wongsirisuwan, Nichapa Lerthirunvibul
article en

Abstract

Introduction BioGlue® (CryoLife, Inc, Kennesaw, GA), despite being claimed to be a safe and harmless sealant, reportedly has several adverse effects including surgical wound dehiscence. This study aimed to examine the factors that may contribute to this unfavorable outcome in cranial surgery. Methods A retrospective cross-sectional analysis was conducted on patients who underwent brain surgery with the use of BioGlue® between January 2015 and December 2022. One hundred and two individuals were enrolled and classified into two categories based on the incidence of surgical wound complications. The patients' demography, operative details, and the nature of their surgical wound problems were evaluated. Results Out of 102 individuals, 15 experienced postoperative wound complications. Fluid resembling pus was noted; however, laboratory cultures yielded negative results. Complications were significantly more prevalent (seven times higher) among individuals utilizing BioGlue® in proximity to titanium plates for skull defect correction. Patients using the 5 mL pre-filled BioGlue® device had a 2.8 times higher likelihood of complications than the 2 mL version. Using the patient's cranial bone as a barrier during surgery reduced the risk of complications. Conclusions Neurosurgeons should note possible adverse reactions of using a sealant for cranial surgery that include inflammation and wound separation. Treatment should include thorough cleansing and complete removal of BioGlue®. Two prevalent risk factors were the close proximity (direct contact) of BioGlue® to the adjacent titanium plate used for covering skull defect and the volume of sealant used (5 mL or 2 mL).

CureusVol. 16(12)
Thammasat University (TH), King Chulalongkorn Memorial Hospital (TH), Rajavithi Hospital (TH), Rangsit University (TH)
Zero hunger
Openalex Percentile: Top 58%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.