Evaluating the Role of GPT-4 and GPT-4o in the Detectability of Chest Radiography Reports Requiring Further Assessment

Purpose The aim of this study is to investigate the capability of generative pre-trained transformer 4 (GPT-4) and GPT-4o in identifying chest radiography reports requiring further assessment. Materials and methods This retrospective study included 100 cases from the National Institutes of Health chest radiography dataset, including 50 abnormal and 50 normal cases. A radiologist blinded to the study's purpose interpreted and reported the radiological findings for each case in English and separately determined the necessity for further assessment based on predefined criteria as referential standards. The radiology reports were then input into GPT-4 and GPT-4o models, accompanied by a prompt to identify cases requiring further assessment. This procedure was repeated five times in separate sessions for each model. Overall accuracy, sensitivity, and specificity of the necessity for further assessment were assessed using McNemar's test. Positive and negative predictive values were assessed using Fisher's exact test and Chi-square test, respectively. Results A total of 100 cases were included (mean age of 49.4 years ± 15.4 [standard deviation]; 56 women). Among them, 44 were judged by the radiologist to require further assessment. Across the five sessions, 19.6% and 35.8% of the cases were judged to require further assessment by GPT-4 and GPT-4o, respectively. The sensitivity, accuracy, and negative predictive value of GPT-4o (74.5%, 85.8%, and 82.6%, respectively) were all significantly higher than those of GPT-4 (44.5%, 75.6%, and 69.7%, respectively) (<i>p</i> < 0.001). The specificity and positive predictive value of GPT-4 (100% and 100%, respectively) were significantly higher than that of GPT-4o (94.6% and 91.6%, respectively) (<i>p</i> < 0.001). Conclusion GPT-4o showed acceptable performance in detecting chest radiography reports requiring further assessment.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-12-11
DOI
https://doi.org/10.7759/cureus.75532
Citations
5
Primary Topic
COVID-19 diagnosis using AI
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Role of GPT-4 and GPT-4o in the Detectability of Chest Radiography Reports Requiring Further Assessment

Ryo Kurokawa, Osamu Abe, Masafumi Kaiume, Mariko Kurokawa et al.
5 citations
Cureus
COVID-19 diagnosis using AI
2.02
article

Evaluating the Role of GPT-4 and GPT-4o in the Detectability of Chest Radiography Reports Requiring Further Assessment

Ryo Kurokawa, Osamu Abe, Masafumi Kaiume, Mariko Kurokawa, Wataru Gonoi, Yuta Nakamura, Jun Kanzawa, Yuki Sonoda
article en
5 citations

Abstract

Purpose The aim of this study is to investigate the capability of generative pre-trained transformer 4 (GPT-4) and GPT-4o in identifying chest radiography reports requiring further assessment. Materials and methods This retrospective study included 100 cases from the National Institutes of Health chest radiography dataset, including 50 abnormal and 50 normal cases. A radiologist blinded to the study's purpose interpreted and reported the radiological findings for each case in English and separately determined the necessity for further assessment based on predefined criteria as referential standards. The radiology reports were then input into GPT-4 and GPT-4o models, accompanied by a prompt to identify cases requiring further assessment. This procedure was repeated five times in separate sessions for each model. Overall accuracy, sensitivity, and specificity of the necessity for further assessment were assessed using McNemar's test. Positive and negative predictive values were assessed using Fisher's exact test and Chi-square test, respectively. Results A total of 100 cases were included (mean age of 49.4 years ± 15.4 [standard deviation]; 56 women). Among them, 44 were judged by the radiologist to require further assessment. Across the five sessions, 19.6% and 35.8% of the cases were judged to require further assessment by GPT-4 and GPT-4o, respectively. The sensitivity, accuracy, and negative predictive value of GPT-4o (74.5%, 85.8%, and 82.6%, respectively) were all significantly higher than those of GPT-4 (44.5%, 75.6%, and 69.7%, respectively) (<i>p</i> < 0.001). The specificity and positive predictive value of GPT-4 (100% and 100%, respectively) were significantly higher than that of GPT-4o (94.6% and 91.6%, respectively) (<i>p</i> < 0.001). Conclusion GPT-4o showed acceptable performance in detecting chest radiography reports requiring further assessment.

CureusVol. 16(12)
University of Tokyo Hospital (JP), The University of Tokyo (JP)
Good health and well-being
Openalex Percentile: Top 12%
COVID-19 diagnosis using AI
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.