Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers

Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-12-01
DOI
https://doi.org/10.1063/5.0224783
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers

Peter Beyer, I. Coffey, P. Puglia, P. Carvalho et al.
Review of Scientific Instruments
Magnetic confinement fusion research
article

Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers

Peter Beyer, I. Coffey, P. Puglia, P. Carvalho, K. Lawson, C. Reux, U. Sheikh, H. Meister, N. Schoonheere
article en

Abstract

Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.

Review of Scientific InstrumentsVol. 95(12)
Aix-Marseille Université (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Culham Science Centre (GB), CEA Cadarache (FR), Max Planck Institute for Plasma Physics (DE), École Polytechnique Fédérale de Lausanne (CH)
EUROfusion
Affordable and clean energy
Openalex Percentile: Top 94%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.