The determination of euglobulin clot lysis time reference intervals in Beckton Dickinson and Kima 3.2% sodium citrate coagulation tubes

Enhanced fibrinolysis or hyperfibrinolysis may lead to life-threatening blood loss, while reduced activity may contribute to thrombosis. Euglobulin clot lysis time (ECLT) is a manual method that measures plasma fibrinolytic activity and is considered the gold standard. However, the data on reference interval is scarce and outdated. We have employed one-sided reference interval (>3 h) since the implementation of ECLT in our laboratory; therefore, we aimed to establish reliable ECLT reference interval and to explore the possible preanalytical influence of different blood collection tubes on the established ECLT reference interval. Establishing a reference interval for fibrinolysis was performed according to CLSI EP28-A3c guidelines by employing a posteriori direct sampling technique. The predefined exclusion criteria included a history of malignant or hepatobiliary disease, a history of deep vein thrombosis/pulmonary embolism (DVT/PE), an acute inflammatory state at the time of the venipuncture. We collected vein blood samples in Vacutest plastic coagulation tubes (Kima, Italy) and Vacutainer glass coagulation tubes (Beckton Dickinson, USA) containing 0.109 mol/l buffered trisodium citrate as an anticoagulant at a blood-to-anticoagulant ratio 9 : 1. We calculated two-sided reference interval and presented as 2.5th and 97.5th percentiles. ECLT values did not differ between sexes or the types of tubes enrolled in the study ( P = 0.8979). The established reference interval ranged from 130 to 297 min for the KIMA Vacutest tube and from 120 to 292 min for the BD Vacutainer tube. The established ECLT reference interval differed significantly from the currently used cut-off value in our laboratory, thus enabling the assessment of hyperfibrinolysis by employing double-sided reference interval.

Authors

Institutions

Publication Details

Journal
Blood Coagulation & Fibrinolysis
Published
2024-11-18
DOI
https://doi.org/10.1097/mbc.0000000000001334
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The determination of euglobulin clot lysis time reference intervals in Beckton Dickinson and Kima 3.2% sodium citrate coagulation tubes

Edvard Galić, Ivona Kuktić, Vanja Radišić Biljak, Andrea Saračević et al.
Blood Coagulation & Fibrinolysis
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

The determination of euglobulin clot lysis time reference intervals in Beckton Dickinson and Kima 3.2% sodium citrate coagulation tubes

Edvard Galić, Ivona Kuktić, Vanja Radišić Biljak, Andrea Saračević, Ognjen Čančarević, Ante Pašalić
article en

Abstract

Enhanced fibrinolysis or hyperfibrinolysis may lead to life-threatening blood loss, while reduced activity may contribute to thrombosis. Euglobulin clot lysis time (ECLT) is a manual method that measures plasma fibrinolytic activity and is considered the gold standard. However, the data on reference interval is scarce and outdated. We have employed one-sided reference interval (>3 h) since the implementation of ECLT in our laboratory; therefore, we aimed to establish reliable ECLT reference interval and to explore the possible preanalytical influence of different blood collection tubes on the established ECLT reference interval. Establishing a reference interval for fibrinolysis was performed according to CLSI EP28-A3c guidelines by employing a posteriori direct sampling technique. The predefined exclusion criteria included a history of malignant or hepatobiliary disease, a history of deep vein thrombosis/pulmonary embolism (DVT/PE), an acute inflammatory state at the time of the venipuncture. We collected vein blood samples in Vacutest plastic coagulation tubes (Kima, Italy) and Vacutainer glass coagulation tubes (Beckton Dickinson, USA) containing 0.109 mol/l buffered trisodium citrate as an anticoagulant at a blood-to-anticoagulant ratio 9 : 1. We calculated two-sided reference interval and presented as 2.5th and 97.5th percentiles. ECLT values did not differ between sexes or the types of tubes enrolled in the study ( P = 0.8979). The established reference interval ranged from 130 to 297 min for the KIMA Vacutest tube and from 120 to 292 min for the BD Vacutainer tube. The established ECLT reference interval differed significantly from the currently used cut-off value in our laboratory, thus enabling the assessment of hyperfibrinolysis by employing double-sided reference interval.

Blood Coagulation & FibrinolysisVol. 36(1)
University of Zagreb (HR), Klinička bolnica "Sveti Duh" (HR)
Openalex Percentile: Top 71%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.