Ultra-high-resolution 40 keV virtual monoenergetic imaging using spectral photon-counting CT in high-risk patients for coronary stenoses

Question Use of low virtual mono-energetic images at 40 keV using spectral dual-energy and photon-counting CT systems is not yet established for diagnosing coronary artery stenosis. Findings UHR 40 keV SPCCT enhances diagnostic accuracy in coronary artery assessment. Clinical relevance By combining spectral sensitivity with lower virtual mono-energetic imaging and ultra-high spatial resolution, SPCCT enhances coronary artery assessment, potentially leading to more accurate diagnoses and better patient outcomes in cardiovascular imaging.

Authors

Institutions

Publication Details

Journal
European Radiology
Published
2024-12-11
DOI
https://doi.org/10.1007/s00330-024-11237-x
Citations
6
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-high-resolution 40 keV virtual monoenergetic imaging using spectral photon-counting CT in high-risk patients for coronary stenoses

Guillaume Fahrni, Sara Boccalini, David C. Rotzinger, Hugo Lacombe et al.
6 citations
European Radiology
Advanced X-ray and CT Imaging
1.11
article

Ultra-high-resolution 40 keV virtual monoenergetic imaging using spectral photon-counting CT in high-risk patients for coronary stenoses

Guillaume Fahrni, Sara Boccalini, David C. Rotzinger, Hugo Lacombe, Salim Aymeric Si-Mohamed, Marjorie Villien, Antoine Robert, Angèle Houmeau, Fabien de Oliveira, P. Douek, Florie Francart
article en
6 citations

Abstract

Question Use of low virtual mono-energetic images at 40 keV using spectral dual-energy and photon-counting CT systems is not yet established for diagnosing coronary artery stenosis. Findings UHR 40 keV SPCCT enhances diagnostic accuracy in coronary artery assessment. Clinical relevance By combining spectral sensitivity with lower virtual mono-energetic imaging and ultra-high spatial resolution, SPCCT enhances coronary artery assessment, potentially leading to more accurate diagnoses and better patient outcomes in cardiovascular imaging.

European RadiologyVol. 35(6)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), Lyon College (US), Hospices Civils de Lyon (FR), DMS Imaging (France) (FR), Hôpital Louis Pradel (FR), Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (FR), Philips (France) (FR), Institut National des Sciences Appliquées de Lyon (FR), University of Lausanne (CH)
European Commission, Centre Hospitalier Universitaire Vaudois, Schweizerische Gesellschaft für Radiologie, Horizon 2020 Framework Programme, European Research Council, HORIZON EUROPE European Research Council
Affordable and clean energy
Openalex Percentile: Top 24%
Advanced X-ray and CT Imaging
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.