Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery

Cardiac output can be estimated non-invasively by electrical cardiometry with the ICON® monitor (Osypka Medical GmbH, Berlin, Germany). Conflicting results have been reported regarding the cardiac output measurement performance of electrical cardiometry. In this prospective method comparison study, we compared cardiac output measured using electrical cardiometry (EC-CO; test method) with cardiac output measured using intermittent pulmonary artery thermodilution (PATD-CO; reference method) in patients after coronary artery bypass graft (CABG) surgery. We calculated the mean of the differences with 95%-limits of agreement (95%-LOA) and their corresponding 95%-confidence intervals (95%-CI) using Bland-Altman analysis and calculated the percentage error. We also analyzed trending using four-quadrant plot analysis. We analyzed 157 paired cardiac output measurements of 41 patients. Mean ± standard deviation PATD-CO was 5.1 ± 1.3 L/min and mean EC-CO was 5.3 ± 1.3 L/min. The mean of the differences ± SD between PATD-CO and EC-CO was -0.2 (95%-CI -0.5 to 0.2) ± 1.2 L/min with a lower 95%-LOA of -2.6 (95%-CI -3.1 to -2.0) L/min and an upper 95%-LOA of 2.3 (95%-CI 1.6 to 2.9) L/min. The percentage error was 47% (95%-CI, 37 to 56%). The concordance rate for cardiac output changes was 48%. In this study, the agreement between EC-CO and PATD-CO was not clinically acceptable in patients after CABG surgery. The trending ability of EC-CO was poor.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2024-12-11
DOI
https://doi.org/10.1007/s10877-024-01246-y
Citations
5
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery

Pischtaz Adel Tariparast, Moritz Flick, Gillis Greiwe, Alexander Hapfelmeier et al.
5 citations
Journal of Clinical Monitoring and Computing
Hemodynamic Monitoring and Therapy
2.86
article

Electrical cardiometry for non-invasive cardiac output monitoring: a method comparison study in patients after coronary artery bypass graft surgery

Pischtaz Adel Tariparast, Moritz Flick, Gillis Greiwe, Alexander Hapfelmeier, Niklas Neumann, Bernd Saugel, Reham Saad
article en
5 citations

Abstract

Cardiac output can be estimated non-invasively by electrical cardiometry with the ICON® monitor (Osypka Medical GmbH, Berlin, Germany). Conflicting results have been reported regarding the cardiac output measurement performance of electrical cardiometry. In this prospective method comparison study, we compared cardiac output measured using electrical cardiometry (EC-CO; test method) with cardiac output measured using intermittent pulmonary artery thermodilution (PATD-CO; reference method) in patients after coronary artery bypass graft (CABG) surgery. We calculated the mean of the differences with 95%-limits of agreement (95%-LOA) and their corresponding 95%-confidence intervals (95%-CI) using Bland-Altman analysis and calculated the percentage error. We also analyzed trending using four-quadrant plot analysis. We analyzed 157 paired cardiac output measurements of 41 patients. Mean ± standard deviation PATD-CO was 5.1 ± 1.3 L/min and mean EC-CO was 5.3 ± 1.3 L/min. The mean of the differences ± SD between PATD-CO and EC-CO was -0.2 (95%-CI -0.5 to 0.2) ± 1.2 L/min with a lower 95%-LOA of -2.6 (95%-CI -3.1 to -2.0) L/min and an upper 95%-LOA of 2.3 (95%-CI 1.6 to 2.9) L/min. The percentage error was 47% (95%-CI, 37 to 56%). The concordance rate for cardiac output changes was 48%. In this study, the agreement between EC-CO and PATD-CO was not clinically acceptable in patients after CABG surgery. The trending ability of EC-CO was poor.

Journal of Clinical Monitoring and ComputingVol. 39(2)
Universität Hamburg (DE), Outcomes Research Consortium (US), University Medical Center Hamburg-Eppendorf (DE), Technical University of Munich (DE)
No poverty
Openalex Percentile: Top 9%
Hemodynamic Monitoring and Therapy
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.